China

雷竞技appFluke 117/323 Electricians Combo Kit, Digital Multimeter and Clamp Meter

  • 雷竞技appElectricians Fluke 117/323 Multimeter Combo Kit - 1
  • 雷竞技appFluke 323 True RMS Clamp Meter
  • F - 323 Clamp Meter

The main features

  • The right combination of tools in The an electrician needs on The job
  • Multimeter and clamp meter, test leads, TPAK and their case
  • 117: a wide array of measurement options all the packed into one tool
  • 323: take measurements easily in tight cable compartments

Produc雷竞技appts overview: Fluke 117/323 Electricians Combo Kit, Digital Multimeter and Clamp Meter

Having the right tools for the job is essential. Having them when you need them is even better. Arrive on every jobsite prepared with the 雷竞技appelectricians Fluke 117/323 multimeter and clamp meter combo kit. The two test tools difference you the power of a versatile, rugged multimeter combined with a fast - acting, general - purpose clamp meter.

Been you work in residential electricity or ltd. electrical, both of these test tools are a good fit for the work you need to complete. The kit includes

  • 雷竞技appFluke 117 digital multimeter
  • 雷竞技appFluke 323 clamp meter
  • Tl175 test leads
  • TPAK ToolPak magnetic meter hanger
  • Soft is their case

The 雷竞技appFluke 117 digital multimeterIs built to make your life easier with the features like:

  • Non - contact voltage detection
  • AutoV/LoZ function
  • Min/Max/business readings
  • Frequency measurements
  • Capacitance measurements

In order to ensure you 're ready to go on many jobsites, the 117 is certified for use In CAT III 600 V environments.

The 雷竞技appFluke 323 clamp meterIs a good basic troubleshooting tool for ltd. and residential electricians. It includes true RMS measurements, optimized ergonomics and a large display for efficient troubleshooting. The small clamp is designed to make measurements in tight cable compartments easier on you and It 's ideally suited for The current measurements of up to 400 a or voltage measurements up to 600 V.

Together, the 雷竞技appFluke 117 Multimeter and Electrician 's True - 323 RMS Clamp Meter difference electricians easy to use, time - saving tools for the work.

Produc雷竞技appt specifications: Fluke 117/323 Electricians Combo Kit, Digital Multimeter and Clamp Meter

雷竞技appFluke 117 Digital Multimeter

Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection, 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
The Fuse for input A 11. A, 1000 V FAST Fuse 雷竞技app(Fluke PN 803293).
The Display Digital: 6000 counts, 4 updates per second
The Bar graph 32 33 segments, updates per second
Operating temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
'type 9 volt Alkaline, NEDA 1604 a/IEC 6 lr61
'life 400 hours of typical, with backlight
Accuracy Specifications
DC millivolts The Range/Resolution 600.0 mV / 0.1 mV
Accuracy Plus or minus ([% of reading] + [counts]) : 0.5% + 2
DC volts The Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy Plus or minus ([% of reading] + [counts]) : 0.5% + 2
Auto volts The Range/Resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts creates True RMS The Range/Resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts creates True RMS The Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity The Range/Resolution Ω Ω / 1, 600
Accuracy Beeper on < 20 Ω off > 250 Ω;Detects opens the or shorts of
500 mu s or longer.
Ohms The Range/Resolution 600.0 Ω / 0.1 Ω
6.000 k Ω Ω / 0.001 k
60.00 k Ω Ω / 0.01 k
600.0 k Ω Ω / 0.1 k
Ω 6.000 M / 0.001 M Ω
Accuracy 0.9% + 1
The Range/Resolution Ω 40.00 M / 0.01 M Ω
Accuracy 5% + 2
Diode test The Range/Resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance The Range/Resolution 1000 nF / 1 nF
10.00 u F / 0.01 u F
100.0 u F / 0.1 u F
9999 mu F u F / 1
100 mu to 1000 mu F F
Accuracy 1.9% + 2
The Range/Resolution > 1000 mu F
Accuracy 5% + 20%
Lo - Z capacitance The Range 1 nF to 500 mu F
Accuracy 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz) The Range/Resolution 6.000 A / 0.1 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds Max
DC amps The Range/Resolution 6.000 0.01 0.1 A10.00 A/A/A
Accuracy 1.0% + 3
20 A continuous overload for 30 seconds Max
Hz (V or A input) squared The Range/Resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

1. All AC voltage ranges except Auto - V/LoZ are specified from 1% to 100% of the range. The Auto - V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.

    • Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. The Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
  • Temperature Range/Resolution: - 40 ° F to 752 ° F / 0.2 ° F.
Mechanical and General Specifications
The Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g
giant 3 years

雷竞技appFluke 323 True RMS Clamp Meter

Specifications
AC current The Range 400.0 A
Accuracy 2% plus or minus 5 who leads
(45 Hz to 65 Hz)
2.5% plus or minus 5 who leads
(65 Hz to 400 Hz)
The AC voltage The Range 600.0 V
Accuracy 1.5% plus or minus 5 who leads
The DC voltage The Range 600.0 V
Accuracy 1.0% plus or minus 5 who leads
To hold The Range/Resolution 400.0 Ω Ω / 4000
Accuracy 1.0% plus or minus 5 who leads
Continuity 70 or less Ω
AC response True RMS
The Data hold Yes
The Size H x W x D (mm) 207 x 75 x 34
Max wire diameter 30 mm (MCM) 600
Weight 265 g
The Category rating The CAT III 600 V
The CAT IV 300 V
giant Two - year

Mode雷竞技appl: Fluke 117/323 Electricians Combo Kit, Digital Multimeter and Clamp Meter

雷竞技appFluke 117/323 Kit
雷竞技appElectricians Fluke 117/323 Multimeter Combo Kit

Includes:

  • 雷竞技appFluke 117 Digital Multimeter
  • 雷竞技appFluke 323 True RMS Clamp Meter