雷竞技appFluke 117 Multimeter and PRV240 Proving Unit Kit
The main features
- True RMS electrician - 's digital multimeter with non - contact voltage detection, AutoVolt automatic ac/dc voltage selection
- Reduces the risk of shock and arc flash by validating the functionality of the test tools without placing yourself in a potentially hazardous electrical environment
Produc雷竞技appts overview: Fluke 117 Multimeter and PRV240 Proving Unit Kit
The 雷竞技appFluke 117 multimeter and PRV240 Proving Unit Kit combines a general - purpose electrician's digital multimeter with a portable, pocket - sized, '- powered voltage source that provides a safe method to verify that your electrical test tool is operating properly before you conduct any live tests.
雷竞技appFluke 117 Electrician 's Multimeter
The 雷竞技appFluke 117 Electricians Multimeter includes integrated non - contact voltage detection, AutoVolt and LoZ functions provides for faster - and more accurate readings. It is a compact true - RMS meter for demanding applications like ltd. buildings, hospitals, and schools.
雷竞技appFluke 117 key functions provides
Integrated VoltAlert ™ technology for fast, the go/no go non - contact voltage detection. The Features AutoVolt ac/dc voltage automatic selection
- Provides low input impedance to help prevent false readings due to ghost voltage
- Provides the Min/Max/business to record signal fluctuations
- The CAT III 600 V safety rated
PRV240 Proving Unit
The 雷竞技appFluke PRV240 Proving Unit is a portable, pocket - sized, '- powered voltage source. It is unique in that It sources stable ac and dc voltages for both LoZ and HiZ instruments.
PRV240 Proving Unit key functions provides
A single leds are functionality, making this unit A simple - to - use solution for complying with TBT verification of your test tool. The Voltage is sourced through recessed contacts that are activated when test the probes are inserted, preventing accidental contact.
- Includes TPak ™ Magnetic Hanging Strap
- Long 'life - 5000 tests per set of four AA batteries
Produc雷竞技appt specifications: Fluke 117 Multimeter and PRV240 Proving Unit Kit
Specifications | |
---|---|
Maximum voltage between any terminal and earth ground | 600 V |
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: the CAT III 600 v |
The Fuse for input A | 11. A, 1000 V FAST Fuse 雷竞技app(Fluke PN 803293). |
The Display | Digital: 6000 counts, 4 updates per second |
The Bar graph | 32 33 segments, updates per second |
Operating temperature | - 10 ° C to + 50 ° C |
Storage temperature | To 40 ° C to + 60 ° C |
'type | IEC 6 lr61 9 volt Alkaline |
'life | 400 hours of typical, with backlight |
Accuracy Specifications | ||
---|---|---|
DC millivolts | The Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | Plus or minus ([% of reading] + [counts]) : 0.5% + 2 | |
DC volts | The Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
Accuracy | Plus or minus ([% of reading] + [counts]) : 0.5% + 2 | |
Auto volts | The Range/resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
AC millivolts creates True RMS | The Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
AC volts creates True RMS | The Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
Continuity | The Range/resolution | Ω Ω / 1, 600 |
Accuracy | Beeper on < 20 Ω off > 250 Ω detects opens the or shorts of 500 mu s or longer. | |
Ohms | The Range/resolution | 600.0 Ohms Range/resolution Ω Ω / 0.1 6.000 k Ω Ω / 0.001 k 60.00 k Ω Ω / 0.01 k 600.0 k Ω Ω / 0.1 k Ω 6.000 M / 0.001 M Ω |
Accuracy | 0.9% + 1 | |
The Range/resolution | Ω 40.00 M / 0.01 M Ω | |
Accuracy | 5% + 2 | |
Diode test | The Range/resolution | |
Accuracy | 0.9% + 2 | |
Capacitance | The Range/resolution | 1000 nF / 1 nF 10.00 u F / 0.01 u F 100.0 u F / 0.1 u F 9999 mu F u F / 1 100 mu to 1000 mu F F |
Accuracy | 1.9% + 2 | |
The Range/resolution | > 1000 mu F | |
Accuracy | 5% + 20% | |
Lo - Z capacitance | The Range | 1 nF to 500 mu F |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500 Hz) | The Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds Max |
|
DC amps | The Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds Max |
|
Hz (V or A input) squared | The Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto - V/LoZ are specified from 1% to 100% of the range. The Auto - V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. The Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. The Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: - 40 ° F to 752 ° F / 0.2 ° F. |
Mechanical and General Specifications | |
---|---|
The Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
Weight | 550 g |
giant | 3 years |
雷竞技appFluke PRV240 Proving Unit
The General Specifications | ||
---|---|---|
The Output voltage | 240 V ac RMS or dc | 1 M Ω plus or minus 10% or greater |
LoZ > 3 k Ω load | 60 V ac typical 50 V ac RMS minimum |
|
The LED power indicator | Turns on when the output voltage is present | |
' | 4 AA Alkaline batteries NEDA | 24. A IEC LR03 |
'life | (5-5000 second duration) test cycles with > 1 M Ω load, 300 tests minimum with > 3 k Ω load | |
Operating temperature | - 10 ° C to + 50 ° C | |
Operating humidity | 0% to 90% (0 ° to 35 ° C) C 0% to 70% (55 ° to 35 ° C C) |
|
Operating led | 2000 m | |
Dimensions | 11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2 | |
Weight | 0.23 kg (8 oz) includes batteries | |
Safety | IEC61010 IEC61010-1, - 2-030 | |
giant | One - year | |
Electromagnetic Compatibility (EMC) | IEC 61326-1 | Portable EM environment;CISPR 11, Group 1, Class A |
US (FCC) | 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103 | |
Chesapeake (KCC) | Class A Equipment (Industrial - & Communication Equipment) | |
This product meets the requirements for industrial (Class A) electromagnetic wave equipment and the seller or the user should take notice of it. This equipment is intended for use in business environments and not to be, informs in homes. |
Mode雷竞技appl: Fluke 117 Multimeter and PRV240 Proving Unit Kit
Includes:
Electrician 's Multimeter with Non - Contact Voltage
- 4 mm silicone test lead the set
- 9 volt Alkaline '(installed)
- Holster
- The User manual
雷竞技appFluke PRV240 Proving Unit
- TPAK hanging strap
- Four AA batteries
- Instruction sheet