China

雷竞技appFluke 12 e + multi-function multimeter

  • 雷竞技appFluke 12 e + Multifunction Multimeter - 1
  • 雷竞技appFluke 12 e + Multifunction Multimeter - 2
  • 雷竞技appFluke 12 e + Multifunction Multimeter - 3
  • 雷竞技appFluke 12 e + Multifunction Multimeter - 4
  • 雷竞技appFluke 12 e + Multifunction Multimeter - 5

The main features

  • Complete measurement functions:

Ac/dc voltage, ac/dc current, ma/microamps, resistors, capacitors, diodes, on and off

  • 0.5% dc accuracy;
  • Large LCD display 4000 words
  • Automatic and manual range is optional
  • Bright white backlight
  • Automatic power saving mode
  • Reading showed keep
  • Removable shockproof sheath
  • Overvoltage security levels: CATIII 600 v
  • Test pens and safety levels: CATIII 600 v
  • Magnetic hung with compatible
  • Three years of quality assurance
The spot
selections679.00
Tax-inclusive price
Fluke authentic guarantee
With $200 free shipping
Enjoy the return within 7 days

Produc雷竞技appts overview: Fluke 12 e + multi-function multimeter

雷竞技app12 e + inherits the Fluke Fluke - digital multimeter precision, durability, security of excellent quality, widely used in industrial manufacturing, commercial buildings in the areas of power electronics, electrical measurement and maintenance, is the ideal testing tools of professional engineers.

Produc雷竞技appt specifications: Fluke 12 e + multi-function multimeter

Can keep 1 year after the calibration accuracy, the work temperature of 18 ° C to 28 ° C, relative humidity of 0% to 75%.Accuracy specification form is as follows:
Plus or minus (reading % + the least significant digits).

function range The resolution of the precision
Ac voltage 4.000 V 0.001 V 1.0% + 3
(40 Hz and 500 Hz) creates 40.00 V 0.01 V
400.0 V 0.1 V
1000 v 1 V
Dc voltage 4.000 V 0.001 V 0.5% + 3
40.00 V 0.01 V
1000 v 1 V
Ac voltage (mv) 400.0 mV 0.1 mV 3.0% + 3
Dc voltage (mv) 400.0 mV 0.1 mV 1.0% + 10
Diode test squared 2.000 V 0.001 V 10%
resistance 400.0 Ω 0.1 Ω 0.5% + 3
(ohm) 4.000 k Ω 0.001 k Ω 0.5% + 2
40.00 k Ω 0.01 k Ω 0.5% + 2
400.0 k Ω 0.1 k Ω 0.5% + 2
4.000 M Ω 0.001 M Ω 0.5% + 2
40.00 M Ω 0.01 M Ω 1.5% + 3
Capacitance after 40.00 the nF 0.01 the nF 2% + 5
400.0 the nF 0.1 the nF 2% + 5
4.000 u F 0.001 u F 5% + 5
40.00 u F 0.01 u F 5% + 5
400.0 u F 0.1 u F 5% + 5
1000 mu F 1 u F 5% + 5
Alternating current mu A 400.0 mu A 0.1 mu A 1.5% + 3
(40 Hz and 400 Hz) 4000 mu A 1 mu A
Alternating current mA 40.00 mA 0.01 mA 1.5% + 3
(40 Hz and 400 Hz) 400.0 mA 0.1 mA
Alternating current A 4.000 A 0.001 A 1.5% + 3
(40 Hz and 400 Hz) 10.00 A 0.01 A
Mu A dc current 400.0 mu A 0.1 mu A 1.5% + 3
4000 mu A 1 mu A
Dc current mA 40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA
A dc current 4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A
backlight There are
Creates all current, frequency and duty ratio range is the range of 1% to 100%.Not less than 1% range of input value specified.
Squared, usually open circuit voltage of 2.0 V, short circuit current < 0.6 mA.
After the specification does not include the test leads capacitance and the capacitance plate caused by error (error range is 40 nF, highest 1.5 nF).
function Overload protection Input impedance (nominal value) Common mode rejection ratio Normal mode rejection ratio
Ac voltage 1000 V creates > 10 M Ω < 100 pF In direct current flow, '-
50 Hz or 60 Hz, greater than 60 dB
Ac voltage (mv) 400 mV > 1 m Ω, < 100 pF When 50 Hz or 60 Hz, greater than 80 dB '-
Dc voltage 1000 V creates > 10 M Ω < 100 pF In direct current flow, When 50 Hz or 60 Hz, greater than 60 dB
50 Hz or 60 Hz, greater than 100 dB
Dc voltage (mv) 400 mV > 1 m Ω, < 100 pF When 50 Hz or 60 Hz, greater than 80 dB '-
1106V Hz maximum
General technical indicators
The highest voltage between any terminal and earthing 1000 V
Display (LCD) 4000 count, update 3 times per second
The battery type 15 a, 2 AA, NEDA IEC LR6
Battery life span Minimum 500 hours (LED test mode and 50 hours without load cases.Load case, the battery life depends on the kind of tested LED.)
The temperature
Working temperature 0 ° C to 40 ° C
Storage temperature '- 30 ° to 60 ° C C
Relative humidity
Storage temperature The condensation (< 10 ° C)
10 ° to 30 ° C, C less than or equal to 90% RH.
30 ° C to 40 ° C, less than or equal to 75%
40 M Ω range
10 ° to 30 ° C, C less than or equal to 80% RH.
30 ° C to 40 ° C, less than or equal to 70%
At an altitude of
Working temperature 2000 m
Storage temperature 12000 m
The temperature coefficient of 0.1 X (specified accuracy) / ° C (18 ° C or > < 28 ° C)
The current input fuse protection 440 mA, 1000 V of fuse,雷竞技app Fluke specified parts only.
11. A, 1000 v of fu雷竞技appse, Fluke specified parts only.
Volume (high x width x length) 183 x 91 x 49.5 mm
The weight of the 455 g
security IEC61010, IEC 61010-1-2-030 CAT III 600 V, the CAT II 1000 V, pollution level 2
Electromagnetic environment IEC 61326-1: portable
Electromagnetic compatibility Only applicable in Korea

Mode雷竞技appl: Fluke 12 e + multi-function multimeter

雷竞技appFluke 12 e + multi-function multimeter
雷竞技appFLUKE - 12 e +, DIGITAL MUILTIMETER CATIII (CENTRALIZED PURCHASE)