Produc雷竞技appts overview: Fluke 179/61 digital multimeter with infrared thermometer
Multimeter and Infrared Thermometer Combo Kit
Created for industrial, HVAC, and facility maintenance. The Rugged true - RMS multimeter with a built - in thermometer to troubleshoot electrical and electromechanical the problems plus a laser guided, non - contact infrared thermometer for measuring rotating or energized equipment, the packed in a durable to their case.
Produc雷竞技appt specifications: Fluke 179/61 digital multimeter with infrared thermometer
雷竞技appFluke 179 Digital Multimeter
Specifications | |||
Voltage DC | Accuracy1 | Plus or minus 0.09% (+ 2) | |
Max. Resolution | 0.1 mV | ||
Maximum | 1000 V | ||
Voltage AC | Accuracy1 | Plus or minus 1.0% (+ 3) | |
Max. Resolution | 0.1 mV | ||
Maximum | 1000 V | ||
The Current DC | Accuracy1 | Plus or minus 1.0% (+ 3) | |
Max. Resolution | 0.01 mA | ||
Maximum | 10 A | ||
The Current AC | Accuracy1 | Plus or minus 1.5% (+ 3) | |
Max. Resolution | 0.01 mA | ||
Maximum | 10 A | ||
To hold | Accuracy1 | Plus or minus 0.9% (+ 1) | |
Max. Resolution | 0.1 Ω | ||
Maximum | 50 M Ω | ||
Capacitance | Accuracy1 | Plus or minus 1.2% (+ 2) | |
Max. Resolution | 1 nF | ||
Maximum | 10000 (including F | ||
Frequency | Accuracy1 | Plus or minus 0.1% (+ 1) | |
Max. Resolution | 0.01 Hz | ||
Maximum | 100 kHz | ||
Temperature | Accuracy1 | Plus or minus 1.0% (+ 10) | |
Max. Resolution | 0.1 ° c. | ||
The Range | To 40 ° C / 400 ° C | ||
1. The Accuracies are best Accuracies for each function | |||
Environmental Specifications | |||
Operating temperature | - 10 ° C to + 50 ° C | ||
Storage temperature | - 30 ° C to + 60 ° C | ||
Humidity (without condensation) | 0% - 90% (0 ° C - 35 ° C) 0% - 70% (35 ° C - 50 ° C) |
||
Safety Specifications | |||
Overvoltage category | EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV |
||
Agency approvals | UL, CSA, TUV listed and VDE Pending | ||
Mechanical and General Specifications | |||
The Size | 43 x 90 x 185 mm | ||
Weight | 420 g | ||
giant | Lifetime | ||
'life | Alkaline ~ 200 hours of typical, with backlight |
雷竞技appFluke 61 IR Thermometer
Specifications | ||
Backlit display for use in poorly lit areas | Yes | |
Doesn temperature readings | Yes | |
The Range | 18 to 275 ° C (0 to 525 ° F) | |
MIN/MAX/AVG | N/A | |
Datalogging | N/A | |
Short to spot thewire | 8:1 | |
Hi - Lo alarm | N/A | |
Optional RTD probe (contact temperature measurement) | N/A | |
Emissivity | Fixed at 0.95 | |
Measurement accuracy | 18 ° C (0 ° F) to 1 ° C (30 ° F) | Plus or minus 3 ° C (5 ° F) |
Above 1 ° C (30 ° F to 275 ° C (525 ° F) | Plus or minus 2% of reading or 2 ° C (3.5 ° F) | |
(have the instrument stable between 23-25 ° C) |
Mode雷竞技appl: Fluke 179/61 digital multimeter with infrared thermometer
雷竞技appFluke 179/61 Kit
雷竞技appFluke Industrial 179/61 Multimeter and Infrared Thermometer Combo Kit
Includes:
- 雷竞技appFluke 179 True RMS Multimeter
- 雷竞技appFluke 61 Infrared Thermometer
- C800 Hard Meter and Accessory Case