雷竞技app17 b MAX Fluke digital multimeter
The main features
- Wrong operation acousto-optic alarm, reduce the damage of fuse
- , 1 mm, apex pens and circuit board test
- Wake up any buttons, improve efficiency
- Voltage: 6000 words reading
- Capacitance range: 2000 uf
- CATIII 600 v safe level
- Support the frequency and temperature measurement
Produc雷竞技appts overview: Fluke 17 b MAX digital multimeter
Fluke support Input Alert ™ is the standard tip pens and the first budget multimeter.Function as its Input Alert ™ can reduce burning fuse for wrong operation efficiency decreased and the cost increase, brought by the research and development of tip pens and let the customer can complete fine measurement on the circuit board.
New - maloperation acousto-optic alarm Input Alert ™
- Employees to improve efficiency, reduce field test caused by wrong operation efficiency is reduced, or even cause safety accidents;
- Cost savings, reduce the fuse replacement;
- In noisy environment, the dark through the flash to alarm.
New - tip pens and 1 mm
- In circuit test, 1 mm pen can accurately test the device pin, avoid the short circuit;
- Pens and diameter than ordinary pens and fine 20%, can be more close, meet the test requirements of narrow space;
- Select the tip material, durable, pens and through rigorous testing, the tip is not easy to bend,
- The has protective cap and the cast design;
- 02 and KIT only tip pens and standard.
New - wake up any buttons
- Do not need to rotate the knob to OFF shift to activate dormant instrument, testing more efficient;
- Avoid the callback to the wrong gear.
New - voltage upgrade to 6000 words
New - capacitance to upgrade to the 2000 mu F
New - the buzzer volume increase
parameter | 15 b MAX 01 | 15 MAX 02 b | 15 b MAX KIT | 17 b MAX 01 | 17 b MAX 02 | 17 b MAX KIT |
According to figures | 6000 | |||||
Ac/dc voltage | 1000 v | |||||
Ac/dc current | 10 a | |||||
Ac/dc ma | 400 ma | |||||
resistance | 40 M Ω | |||||
diode | Square root | |||||
On and off | Square root | |||||
capacitance | 2 mf | |||||
frequency | - | 100 KHZ | ||||
The temperature | - | 400 ℃ | ||||
Relative measurement | - | Square root | ||||
Low impedance input LoZ | - | Square root | ||||
Non-contact voltage alarm NCV | - | Square root | ||||
Automatic identification of ac/dc voltage | - | Square root | ||||
Any key wake up | Square root | |||||
Wrong way alarm | Square root | |||||
Ordinary pens and | Square root | - | Square root | Square root | - | Square root |
Point pens and 1 mm | - | Square root | Square root | - | Square root | Square root |
Produc雷竞技appt specifications: Fluke 17 b MAX digital multimeter
Technical specifications | ||||
---|---|---|---|---|
Within one year after the calibration precision, working temperature of 18 ° C to 28 ° C, relative humidity 0% to 75%.Precision specifications in the following format: + (% of [reading] + [least significant digit value]). | ||||
function | range | The resolution of the | precision | |
15 b MAX | 17 b MAX | |||
Ac voltage (40 Hz - 500 Hz)1 | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0% + 3 | 1.0% + 3 |
Ac voltage (mv) | 600.0 mV | 0.1 mV | 3.0% + 3 | 3.0% + 3 |
Dc voltage | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5% + 3 | 0.5% + 3 |
Dc voltage (mv) | 600.0 mV | 0.1 mV | 1.0% + 10 | 1.0% + 10 |
Alternating current mu (40 Hz - 400 Hz)2 | 400.0 mu A 4000 mu A |
0.1 mu A 1 mu A |
1.5% + 3 | 1.5% + 3 |
Alternating current mA (40 Hz - 400 Hz)2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5% + 3 | 1.5% + 3 |
Alternating current A (40 Hz - 400 Hz)2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5% + 3 | 1.5% + 3 |
Mu A dc current2 | 400.0 mu A 4000 mu A |
0.1 mu A 1 mu A |
1.5% + 3 | 1.5% + 3 |
Dc current mA2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5% + 3 | 1.5% + 3 |
A dc current2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5% + 3 | 1.5% + 3 |
Diode test3 | 2.000 V | 0.001 V | 10% | 10% |
The temperature of 4 | 50.0 ° C to 400.0 ° C 0 ° C to 50.0 ° C 55.0 ° C to 0 ° C |
0.1 ° c. | Do not apply | 2% + 1 ° C 2 ° c. 9% + 2 ° C |
Resistance (ohms)5 | 400.0 Ω 4.000 k Ω 40.00 k Ω 400.0 k Ω 4.000 M Ω 40.00 M Ω |
0.1 Ω 0.001 k Ω 0.01 k Ω 0.1 k Ω 0.001 M Ω 0.01 M Ω |
0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 |
0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 |
capacitance6 | 40.00 the nF 400.0 the nF 4.000 u F 40.00 u F 400.0 u F 2000 mu F |
0.01 the nF 0.1 the nF 0.001 u F 0.01 u F 0.1 u F 1 u F |
2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 |
2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 |
frequency1(10 Hz to 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
Do not apply | 0.1% + 3 |
Duty ratio1 | 1% to 99% | 0.10% | Do not apply | 1% typical7 |
On and off sex threshold | - | - | 70 Ω | 70 Ω |
backlight | - | - | There are | There are |
1All alternating current, frequency and duty ratio are specified according to the range of 1% to 100%.Not less than 1% range of input value specified. 2Typical load voltage dc/ac current (including A: 100 (including V/(including A, dc/ac current mA: 2 mV/mA, dc/ac current A: 0.03 V/A 3Usually, the open circuit voltage of 2.0 V, short circuit current < 0.6 mA. 4Support 4 K type thermocouple 5Five typical open circuit voltage of 0.54 V, the maximum short-circuit current 1.8 mA 6Specification does not include for testing wire capacitance and the capacitance error, as a result of the basal (40 nF range could be as high as 1.5 nF). 7Typical case refers to the frequency of 50 Hz or 60 Hz, the duty ratio from 10% to 90%. |
The input features | ||||
---|---|---|---|---|
function | Overload protection | Input impedance (nominal value) | Common mode rejection ratio | Normal mode rejection ratio |
Ac voltage | 1000 V1 | > 10 M Ω, < 100 pF | When 50 Hz or 60 Hz, greater than 60 dB | - |
Ac voltage (mv) | 1000 V1 | > 1 M Ω, < 100 pF | When 50 Hz or 60 Hz, greater than 80 dB | - |
Dc voltage | 1000 V1 | > 10 M Ω, < 100 pF | When 50 Hz or 60 Hz, greater than 100 dB | When 50 Hz or 60 Hz, greater than 60 dB |
Dc voltage (mv) | 1000 V1 | > 1 M Ω, < 100 pF | When 50 Hz or 60 Hz, greater than 80 dB | - |
1106V Hz (maximum) |
General technical indicators | |
The highest voltage between any terminal and earthing | 600 V |
The biggest difference between V port and COM port voltage | 1000 v |
Display (LCD) | 6000 count, update 3 times per second |
The battery type | 2 AA, IEC LR6 |
Battery life | Minimum 500 hours |
The temperature | Working temperature: 0 ° C to 40 ° C; Storage temperature: - 30 ° to 60 ° C C |
Relative humidity | Working humidity: 10 ° to 30 ° C C, relative humidity of 90% or less;30 ° C to 40 ° C, the relative humidity of 75% or less.The condensation (below 10 ° C) |
Working humidity, 40 M Ω range | 10 ° to 30 ° C C, relative humidity of 80% or less;30 ° C to 40 ° C, relative humidity 70% or less |
At an altitude of | Work: the elevation 2000 m;Storage: 12000 m |
The temperature coefficient of | 0.1 X (specified accuracy) / ° C (18 ° C or > < 28 ° C) |
The current input fuse protection | 440 mA, 1000 V type of 雷竞技appfuse, use Fluke specified parts only.11. A, 1000 V type of雷竞技app fuse, use Fluke specified parts only |
Volume (high x width x length) | 183 mm x 91 mm x 49.5 mm |
The weight of the | 455 g |
The IP rating | IP40 |
security | IEC61010, IEC 61010-1-2-030 CAT III 600 V, pollution level 2 |
Electromagnetic environment | IEC 61326-1: portable |
Electromagnetic compatibility | Only applicable in Korea |
Class A equipment (industrial radio and communication equipment)1
11 the product accord with the requirement of industrial (class A) electromagnetic waves, distributor or user should pay attention to this.This equipment is suitable for the working environment, rather than the home environment
Mode雷竞技appl: Fluke 17 b MAX digital multimeter
- TL75 test pens and, with two protective cap
- K type thermocouple temperature sensor
- 2 AA batteries
- The user manual
- TL31 pointed pens and, with two protective cap
- K type thermocouple temperature sensor
- The user manual
- TL75 test pens and, with two protective cap
- TL31 pointed pens and, with two protective cap
- K type thermocouple temperature sensor
- 2 AA batteries
- The user manual