雷竞技appFluke 3000 FC series wireless multimeter
The main features
Wit雷竞技apph a Fluke Connect ® application of Fluke 3000 FC series wireless multimeter can satisfy all needs of convenient test and measure the troubleshooting.
- Ac and dc voltage measurement, up to 1000 V
- Ac and dc current is 0.01 mA resolution
- Connectivity, resistance, diode testing, capacitance and frequency measurement
- Minimum/maximum record
- The CAT III 1000 V, the CAT IV 600 V;IP54
In 雷竞技appaddition, Fluke Connect wireless enabled modules can also be measured ac, dc and ac + dc voltage and temperature, all measurements are shown on the Fluke 3000 FC series wireless multimeter.Selection criteria current clamp pliers or flexible current measuring ac current.Hybrid module, and then will they match your unique measurement needs.The main measurements read main screen, as many as three modules at a time.Modules can 雷竞技appbe used alone, or used as part of the suite Fluke Connect.
Special offers
Produc雷竞技appts overview: Fluke 3000 FC series wireless multimeter
Discovery.Save.To be Shared.
All the data, the scene for a quick.Wit雷竞技apph a Fluke Connect ® application and ShareLive ™ of the Fluke 3000 FC true RMS multimeter wireless video calling.
Because of its 雷竞技appaccuracy, reliability and ease of use, Fluke 3000 FC wireless multimeter become an ideal solution for professional and technical personnel.雷竞技appFluke 3000 FC IV class has passed the 600 V / 1000 V class III in the environment safe use independent test, troubleshoot and repair electrical and electronic systems in many problems in all the required functions.
雷竞技appFluke 3000 FC to provide you with true RMS voltage and current measurements, counting 6000 resolution, manual and automatic range, as well as the frequency, capacitor, resistor and on-off and diode measuring values.In 雷竞技appaddition, 0.09% of the Fluke 3000 FC provides higher accuracy of basic, most from the remote display module of measurement value of the three auxiliary digital display, as well as the bright white light.
Wear less personal protective equipment to the electrical panel near the safe operation
雷竞技appWireless multimeter and Fluke Fluke 3000 FC true RMS Connect wireless testing tools to make tools rather than your body near the charged electrical panel.Simple.Only need to cut off the power of the cabinet, wear personal protective equipment (ppe) and open the panel, you can connect various remote module, including voltage module, current clamp, flexible current loop or thermometer.Then read from a safe distance 3000 FC wireless the reading on the multimeter.You can display up to three wireless module instrument measurement and reading, and through their separated from dangerous situation to reduce the risk of arc flash.
Even 雷竞技appbetter, Fluke 3000 FC series wireless multimeter can send your smartphone measurement data, enables you to save anytime and anywhere returned from the field measurement data and share them with your team.
Search for related events, won't make the job to a halt
Trying to find the cause of the complex problem, the timing is particularly important.Usually you need to measure in one place, and the activities of the view from different parts of the system at the same time.We have雷竞技app solved this problem by Fluke Connect - in a position to Connect your remote module, and then use the Fluke 3000 FC multimeter to measure within the range as far as 20 meters.You will be able to see on a screen in real time remote interaction between test points.You can even download the measured data to PC for further analysis.
雷竞技appFluke Connect and other functions of the FC 3000 multimeter
- Add a laptop and records, analysis and diagnosis.
- Use雷竞技app Fluke Connect wireless module for a period of record, and monitoring for an hour, a shift or circuit load changes in a week time.
- Through a running remote mo雷竞技appdule and download the recorded data, can use Fluke Connect wireless USB adapter to collect data from the record of the module.
- Use your PC to pe雷竞技apprform analysis, and use the Fluke Cloud ™ store and ShareLive ™ video sharing results.View the data or chart, for team members to provide information.
Produc雷竞技appt specifications: Fluke 3000 FC series wireless multimeter
Ac voltage | |||||
Range creates/resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
||||
Precision squared after4 | 45 Hz - 500 Hz | 1.0% + 3 | |||
500 Hz to 1 kHz | 2.0% + 3 | ||||
1. The ac voltage range has been designated as the range of 1% to 100%. 2. The full scale highest do not exceed 500 V the crest factor of 3 or less, at 1000 V linear low crest factor < 1.5. Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading). 4. Do not over 107 V - Hz. |
|||||
Dc voltage, connectivity, resistance, diode test and capacitance | |||||
function | range | The resolution of the | precision | ||
The mV | 600.0 mV | 0.1 mV | 0.09% + 2 | ||
V | 6.000 V | 0.001 V | 0.09% + 2 | ||
60.00 V | 0.01 V | ||||
600.0 V | 0.1 V | ||||
1000 V | 1 V | 0.15% + 2 | |||
Ω | 600 Ω | 1 Ω | < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit. | ||
Ω | 600.0 Ω | 0.1 Ω | 0.5% + 2 | ||
6.000 k Ω | 0.001 k Ω | 0.5% + 1 | |||
60.00 k Ω | 0.01 k Ω | ||||
60.00 k Ω | 0.1 k Ω | ||||
600.0 k Ω | 0.001 M Ω | ||||
50.00 M Ω | 0.01 M Ω | 1.5% + 3 | |||
Diode test | 2.000 V | 0.001 V | 1% + 2 | ||
Including F | 1000 nF | 1 nF | 1.2% + 2 | ||
10.00 u F | 0.01 u F | ||||
100.0 u F | 0.1 u F | ||||
9999 mu of F1 | 1 u F | 10% of the typical | |||
1 under the 9999 mu F range measuring 1000 mu F capacitance, measurement accuracy of 1.2% + 2. | |||||
Ac and dc current | |||||
MA communication (45 Hz to 1 kHz) |
Range creates/ resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA |
|||
precision | 1.5% + 3 | ||||
MA DC squared | Range creates/ resolution | 60.00 mA / 0.01 mA 400.0 mA after / 0.1 mA |
|||
precision | 0.5% + 3 | ||||
1. All alternating current range have been designated as the range of 5% to 100%. 2. Enter the load voltage (typical) : 400 mA input 2 mV/mA. 3. According to the 400 mA specified accuracy, overload of 600 mA. |
|||||
frequency | |||||
Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz |
||||
Precision creates | 0.1% + 1 | ||||
1. Specify voltage frequency up to 99.99 kHz, current frequency up to 10 kHz. | |||||
The input features | |||||
The input features | |||||
function | overload To protect the |
The input impedance (nominal value) |
Common mode rejection ratio (1 k Ω non-equilibrium) | Norm inhibition | |
1100 V RMS | > 10 M Ω < 100 pF | In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB | At 50 Hz or 60 Hz greater than 60 dB | ||
1100 V RMS | > 10 M Ω < 100 pF | In dc and greater than 60 dB when the frequency is 60 Hz | |||
1100 V RMS | > 10 M Ω < 100 pF | In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB | At 50 Hz or 60 Hz greater than 60 dB | ||
Open circuit voltage | Full scale voltage | Typical short-circuit current | |||
To 6 M Ω | 50 M Ω | ||||
1100 V RMS | < 2.7 V DC | < 0.7 V DC | < 0.9 V DC | < 350 mA, | |
1100 V RMS | < 2.7 V DC | 2.000 V dc | < 1.1 mA | ||
MA function | |||||
Overload protection | 44/100 fuse, A, 1000 V, fuse | ||||
overload | 600 mA overload for up to 2 minutes, at least 10 minutes to a halt | ||||
Minimum/maximum record accuracy | |||||
Dc function | Duration of > 350 milliseconds changes in a total of 12 times. | ||||
Communication function | Duration of > 900 milliseconds a total of 40 times of change. | ||||
General technical indicators | |||||
The highest voltage between any terminal and earthing | 1000 V dc or ac RMS | ||||
Ω A input fuse protection | 0.44 A (44/100 A, 440 mA), 1000 V quick fuse, fluke specified components only | ||||
Display (LCD) | Update rate | 4 / SEC. | |||
The volt, ampere, ohm | 6000 times | ||||
frequency | 10000 times | ||||
capacitance | 1000 times | ||||
The battery type | Three AA alkaline batteries, NEDA IEC LR6 15 a | ||||
Battery life | At least 250 hours | ||||
Radio frequency communication | The 2.4 GHZ ISM band | ||||
Radio frequency communication range | In the open air, barrier-free | As far as 20 meters | |||
, gypsum board wall | As far as 6.5 m | ||||
Wall, concrete, or steel electric shell | As far as 3.5 m | ||||
The temperature | Working temperature | - 10 ° C to 50 ° C | |||
Storage temperature | To 40 ° to 60 ° C C | ||||
The temperature coefficient of | The set accuracy 0.1 X () / ° C (18 ° C or > < 28 ° C) | ||||
Relative humidity | From 0% to 90% (0 ° C and 35 ° C) From 0% to 75% (35 ° C to 40 ° C) From 0% to 45% (40 ° C to 50 ° C) |
||||
At an altitude of | Work at an altitude of | 2000 m | |||
Stored at an altitude of | 12000 m | ||||
Electromagnetic compatibility EMI and RFI, EMC (EMC) and RF |
EN 61326-1:6, EN 61326-2 - "06 ETSI V1.7.1 EN 300, 328:2006, ETSI EN 300 489 V1.8.1:2008 The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements FCCID: FCC: T68 - FDMMBLE IC: 6627 - a - FDMMBLE |
||||
Meet safety standards | ANSI/ISA 61010-1 / (82.02.01), 3rd edition CAN/CSA C22.2 No. 61010-1-12:3rd edition UL 61010-1:3 IEC/EN 61010-1:10 |
||||
certification | CSA, the FCC, CE | ||||
Protection (IP) rating | IP54 | ||||
Pollution levels | 2 | ||||
Size (height x width x length) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||||
The weight of the | 340 g (12 oz) | ||||
Warranty period | Three years, | ||||
Is雷竞技app not compatible with Fluke CNX testing tools |
Mode雷竞技appl: Fluke 3000 FC series wireless multimeter
雷竞技appFluke 3000 FC series wireless multimeter
Include:
- True RMS wireless multimeter
- TL175 test conductor
- AC175 alligator clip
Manual + 雷竞技appresource: Fluke 3000 FC series wireless multimeter
- 3000 FC | user manual
- 3000 FC | quick reference guide
- 3000 FC | calibration manual
- 3000 FC | calibration manual addendum
- 3000 FC statement | non-volatile memory
- The a3000 FC | calibration manual
- The a3000 FC | quick reference guide
- A3001 FC | calibration manual
- A3001 FC | quick reference guide
- A3002 FC | calibration manual
- A3002 FC | quick reference guide
- 雷竞技appFluke Connect | quick reference guide
- 雷竞技appFluke Connect wi-fi to Thermal Imager | quick reference guide
- Ir3000 FC | quick reference guide
- PC 3000 FC | instructions page
- T3000 FC | quick reference guide
- T3000 FC | calibration manual
- V3000 FC | calibration manual
- V3000 FC v3001 FC | quick reference guide
- V3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC statement | non-volatile memory