China

雷竞技appFluke 3000 FC/EDA2 combination suite - including instruments and luxury accessories

  • 雷竞技appFluke 3000 FC/EDA2 Combo Kit

The main features

雷竞技appFluke 3000 FC has ruled out fault features and functionality needed for the equipment and factory.

  • Can accurately measure true RMS ac voltage and current of nonlinear load
  • Equipped with a large digital display simulation bar chart
  • Work for the dark display backlight
  • capacitance
  • Record the minimum and maximum values for troubleshooting
  • Can be combined with this kit contained in the magnetic suspension hands free
  • 3 years warranty
  • In 雷竞技appaddition, Fluke Connect wireless enabled modules can also be measured ac, dc and ac + dc voltage and temperature, all measurements are shown on the Fluke 3000 FC series wireless multimeter.Selection criteria current clamp pliers or flexible current measuring ac current.Hybrid module, and then will they match your unique measurement needs.The main measurements read main screen, as many as three modules at a time.Modules can 雷竞技appbe used alone, or used as part of the suite Fluke Connect

All trademarks are the property of their respective owner.When buying is not attached to provide smart phones, wireless services and scheme of the data, 5 GB free.Compatible with 8 or higher system running iOS iPhone 4 s and higher model, the iPhone on (the) and run Android ™ 4.4 x or later versions of the Galaxy S4, the Nexus 5, HTC One.Apple and Apple logo are the Apple in the United States and other countries/regions registered trademark.App Store is a service mark of apple, Google Play is Google the company's trademark.

Produc雷竞技appts overview: Fluke 3000 FC/EDA2 combination suite - including instruments and luxury accessories

Detai雷竞技appls about Fluke Connect »

Now c雷竞技appompatible Fluke Connect ® mobile applications

雷竞技appFluke 3000 FC series wireless multimeter to wireless testing tools rather than your body near the charged electrical panel.Using this tester for enhance security and efficiency.

All the data, the scene for a quick.Wit雷竞技apph a Fluke Connect applications and ShareLive ™ of the Fluke 3000 FC true RMS multimeter wireless video calling.

Because of its 雷竞技appaccuracy, reliability and ease of use, Fluke 3000 FC wireless multimeter become an ideal solution for professional and technical personnel.雷竞技appFluke 3000 FC IV class has passed the 600 V / 1000 V class III in the environment safe use independent test, troubleshoot and repair electrical and electronic systems in many problems in all the required functions.

雷竞技appFluke 3000 FC to provide you with true RMS voltage and current measurements, counting 6000 resolution, manual and automatic range, as well as the frequency, capacitor, resistor and on-off and diode measuring values.In 雷竞技appaddition, 0.09% of the Fluke 3000 FC provides higher accuracy of basic, most from the remote display module of measurement value of the three auxiliary digital display, as well as the bright white light.

Wear less personal protective equipment to the electrical panel near the safe operation

雷竞技appWireless multimeter and Fluke Fluke 3000 FC true RMS Connect wireless testing tools to make tools rather than your body near the charged electrical panel.Simple.Only need to cut off the power of the cabinet, wear personal protective equipment (ppe) and open the panel, you can connect various remote module, including voltage module, current clamp, flexible current loop or thermometer.Then read from a safe distance 3000 FC wireless the reading on the multimeter.You can display up to three wireless module instrument measurement and reading, and through their separated from dangerous situation to reduce the risk of arc flash.

Even 雷竞技appbetter, Fluke 3000 FC series wireless multimeter can send your smartphone measurement data, enables you to save anytime and anywhere returned from the field measurement data and share them with your team.

Search for related events, won't make the job to a halt

Trying to find the cause of the complex problem, the timing is particularly important.Usually you need to measure in one place, and the activities of the view from different parts of the system at the same time.We have雷竞技app solved this problem by Fluke Connect - in a position to Connect your remote module, and then use the Fluke 3000 FC multimeter to measure within the range as far as 20 meters.You will be able to see on a screen in real time remote interaction between test points.You can even download the measured data to PC for further analysis.

雷竞技appFluke 3000 FC multimeter Connect and other functions.

  • Add a laptop and records, analysis and diagnosis.
  • Use雷竞技app Fluke Connect wireless module for a period of record, and monitoring for an hour, a shift or circuit load changes in a week time.
  • Through a running remote mo雷竞技appdule and download the recorded data, can use Fluke Connect wireless USB adapter to collect data from the record of the module.
  • Use your PC to pe雷竞技apprform analysis, and use the Fluke Cloud ™ store and ShareLive ™ video sharing results.View the data or chart, for team members to provide information.

All trademarks are the property of their respective owner.When buying is not attached to provide smart phones, wireless services and scheme of the data, 5 GB free.Compatible with 8 or higher system running iOS iPhone 4 s and higher model, the iPhone on (the) and run Android ™ 4.4 x or later versions of the Galaxy S4, the Nexus 5, HTC One.Apple and Apple logo are the Apple in the United States and other countries/regions registered trademark.App Store is a service mark of apple, Google Play is Google the company's trademark.

Produc雷竞技appt specifications: Fluke 3000 FC/EDA2 integrated suite - including instrument and luxury accessories

Alternating current range have been designated as the range of 5% to 100%.
2. Enter the load voltage (typical) : 400 mA input 2 mV/mA.
3. According to the 400 mA specified accuracy, overload of 600 mA.DC to 60 Hz DC or ac RMS
Ac voltage
Range creates/resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Precision squared after4 45 Hz - 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. The ac voltage range has been designated as the range of 1% to 100%.
2. The full scale highest do not exceed 500 V the crest factor of 3 or less, at 1000 V linear low crest factor < 1.5.
Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading).
4. Do not over 107 V - Hz.
Dc voltage, connectivity, resistance, diode test and capacitance
The mV Range/resolution 600.0 mV / 0.1 mV
precision 0.09% + 2
V Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
precision 0.09% + 2
0.15% + 2
))) Range/resolution Ω Ω / 1, 600
precision < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit.
Ω Range/resolution 600.0 Ω / 0.1 Ω
6.000 k Ω Ω / 0.001 k
60.00 k Ω Ω / 0.01 k
60.00 k Ω Ω / 0.1 k
600.0 k Ω Ω / 0.001 M
Ω 50.00 M / 0.01 M Ω
precision 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range/resolution 2.000 V / 0.001 V
precision 1% + 2
Including F Range/resolution 1000 nF / 1 nF
10.00 u F / 0.01 u F
100.0 u F / 0.1 u F
9999 mu F1 /1 u F
precision 1.2% + 2
10% of the typical
1. Under the 9999 mu F range measuring 1000 mu F capacitance, the measurement accuracy of 1.2% + 2.
Ac and dc current
MA communication
(45 Hz to 1 kHz)
Range creates/ resolution 60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mA
precision 1.5% + 3
MA DC squared Range creates/ resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 0.5% + 3
1. All
frequency
Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Precision creates 0.1% + 1
1. Specify voltage frequency up to 99.99 kHz, current frequency up to 10 kHz.
The input features
Overload protection 1100 V RMS
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
Unbalanced Ω (1 k)
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Overload protection 1100 V RMS
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
Unbalanced Ω (1 k)
> 60 dB
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Overload protection 1100 V RMS
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
Unbalanced Ω (1 k)
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Open circuit voltage
Overload protection 1100 V RMS
Input impedance (nominal value) < 2.7 V DC
Full scale voltage to 6 M Ω
Full scale voltage 50 M Ω
< 0.7 V DC
< 0.9 V DC
Typical short-circuit current < 350 mA,
Overload protection 1100 V RMS
Input impedance (nominal value) < 2.7 V DC
Full scale voltage to 6 M Ω
Full scale voltage 50 M Ω
2.000 V dc
Typical short-circuit current < 1.1 mA
MA function
Overload protection 44/100 fuse, A, 1000 V, fuse
overload 600 mA overload for up to 2 minutes, at least 10 minutes to a halt
Minimum/maximum record accuracy
Dc function Duration of > 350 milliseconds for counting + 12 times of change.
Communication function Duration of > 900 milliseconds for counting + 40 times of change.
General technical indicators
The highest voltage between arbitrary terminals and grounding 1000 V
Ω A input fuse protection 0.44 A (44/100 A, 440 mA), 1000 V quick fuse, fluke specified components only
Display (LCD) Update rate 4 / SEC.
The volt, ampere, ohm 6000 times
frequency 10000 times
capacitance 1000 times
The battery type Three AA alkaline batteries, NEDA IEC LR6 15 a
Battery life At least 250 hours
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
The temperature Working temperature - 10 ° C to 50 ° C
Storage temperature To 40 ° to 60 ° C C
The temperature coefficient of The set accuracy 0.1 X () / ° C (18 ° C or > < 28 ° C)
Relative humidity From 0% to 90% (0 ° C and 35 ° C)
From 0% to 75% (35 ° C to 40 ° C)
From 0% to 45% (40 ° C to 50 ° C)
At an altitude of Work at an altitude of 2000 m
Stored at an altitude of 12000 m
Electromagnetic compatibility
EMI and RFI, EMC (EMC) and RF
EN 61326-1:6, EN 61326-2 - "06
ETSI V1.7.1 EN 300, 328:2006, ETSI EN 300 489
V1.8.1:2008
The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements
FCCID: FCC: T68 - FDMMBLE IC: 6627 - a - FDMMBLE
Meet safety standards ANSI/ISA 61010-1 / (82.02.01), 3rd edition
CAN/CSA C22.2 No. 61010-1-12:3rd edition
UL 61010-1:3
IEC/EN 61010-1:10
certification CSA, the FCC, CE
Protection (IP) rating IP54
Pollution levels 2
Size (height x width x length) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
The weight of the 340 g (12 oz)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

Mode雷竞技appl: Fluke 3000 FC/EDA2 combination suite - including instruments and luxury accessories

FC/EDA2 FLK - 3000
雷竞技appFluke 3000 FC/EDA2 suite
Standard:
  • 雷竞技appFluke 3000 FC, true RMS digital multimeter with backlight
  • 雷竞技appFluke TL910 electrical test probe
  • 雷竞技appFluke TL224 silica gel test line
  • Sure Grip ™ heavy hook probe
  • 雷竞技appFluke C35 lightweight soft carrying bag
  • ToolPak ™ magnetic multimeter accessories
  • The battery has been installed
  • User manual CD

Manual + 雷竞技appresources: Fluke 3000 FC/EDA2 combination suite - including instruments and luxury accessories