China

雷竞技appFluke 3000 FC HVAC systems

  • 雷竞技appFluke 3000 FC HVAC System
  • 雷竞技appFluke 3000 FC Series Wireless Multimeter
  • 雷竞技appFluke 805 FC Vibration Meter
  • 雷竞技appFluke 3000 FC Series Wireless Multimeter

The main features

FC wireless HVAC system provides all of the common electrical parameters measurement

Wit雷竞技apph a Fluke Connect ® application of Fluke 3000 FC series wireless multimeter can satisfy all needs of convenient testing and measuring troubleshooting:

  • Ac and dc voltage measurement, up to 1000 V
  • Ac and dc current is 0.01 mA resolution
  • Connectivity, resistance, diode testing, capacitance and frequency measurement
  • Minimum/maximum record
  • The CAT III 1000 V, the CAT IV 600 V;IP54

雷竞技appFluke a3000 FC wireless communication convenient current clamp module can meet all needs of test and measurement troubleshooting:

  • True RMS ac current clamp table
  • Measured 400 A alternating current (ac)
  • It is used as instrument independently or as part of the system
  • For logging, used to record and save as many as 65000 readings
  • Surge function

Wit雷竞技apph the help of a Fluke t3000 FC wireless type K temperature module, you can:

  • It is used as instrument independently or as part of the system
  • For logging, used to record and save as many as 65000 readings

Produc雷竞技appts overview: Fluke 3000 FC HVAC systems

雷竞技appFluke FC HVAC system enables you to use remote wireless module current and temperature faster, safer and more convenient to electrical panel operations

FC wireless communication current clamp module is connected to your test points, and wireless digital multimeter at FC on the result of the scope of view as far as 20 meters.In addition, you can connect to wireless K type t3000 FC wireless temperature module, and view the remote temperature measurement value.

You'll save time, without resistance.the collect multiple measurements.The three-phase system is measur雷竞技apped using multiple modules, can be used as independent measurement tools, or with other Fluke Connect ® frequent testing module combined into a system.

In short, you can even check module reading through closed electrical panel.In addition, no雷竞技app manual record data, because the Fluke Connect remote module USES optional PC adapter can capture up to 65000 groups of min/Max with timestamp/average readings.雷竞技appFluke Connect wireless test tool also by you in the position of the separation of the test point view reading, to improve safety.

Now, you can get in the operation of the reading on the machinery and equipment, only there is a damage risk measurement module.

Produc雷竞技appt specifications: Fluke 3000 FC HVAC system

雷竞技appFluke 3000 FC series wireless multimeter

* for all specifications: deadline specified for one year after the calibration precision and working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit]).

Detailed technical indicators
Ac voltage
Range creates/resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Precision squared after4 45 Hz - 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All ac voltage range has been designated as the range of 1% to 100%.
2. The full scale highest do not exceed 500 V the crest factor of 3 or less, at 1000 V linear low crest factor < 1.5.
Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading).
4. Do not over 107 V - Hz.
Dc voltage, connectivity, resistance, diode test and capacitance
function
The mV Range/resolution 600.0 mV / 0.1 mV
precision 0.09% + 2
V Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
precision 0.09% + 2
0.15% + 2
))) Range/resolution Ω Ω / 1, 600
precision < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit.
Ω Range/resolution 600.0 Ω / 0.1 Ω
6.000 k Ω Ω / 0.001 k
60.00 k Ω Ω / 0.01 k
60.00 k Ω Ω / 0.1 k
600.0 k Ω Ω / 0.001 M
Ω 50.00 M / 0.01 M Ω
precision 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range/resolution 2.000 V / 0.001 V
precision 1% + 2
Including F Range/resolution 1000 nF / 1 nF
10.00 u F / 0.01 u F
100.0 u F / 0.1 u F
9999 mu F1 /1 u F
precision 1.2% + 2
10% of the typical
Creates under 9999 mu F range measuring 1000 mu F capacitance, the measuring accuracy of 1.2% + 2.
Ac and dc current
function
MA communication
(45 Hz to 1 kHz)
Range creates/ resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 1.5% + 3
MA DC squared Range creates/resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 0.5% + 3
1. All alternating current range has designated range of 5% to 100%.
2. Enter the load voltage (typical) : 400 mA input 2 mV/mA.
3. According to the 400 mA specified accuracy, overload of 600 mA.
frequency
Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Precision creates 0.1% + 1
Creates the specified voltage frequency up to 99.99 kHz, current frequency up to 10 kHz.
The input features
function overload
To protect the
The input impedance
(nominal value)
Common mode rejection ratio (1 k Ω non-equilibrium) Norm inhibition
1100 Vrms > 10 M Ω < 100 pF In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB At 50 Hz or 60 Hz greater than 60 dB
1100 Vrms > 10 M Ω < 100 pF When the dc to 60 Hz, or more than 60 dB At 50 Hz or 60 Hz greater than 60 dB
1100 Vrms > 10 M Ω < 100 pF In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB At 50 Hz or 60 Hz greater than 60 dB
Open circuit voltage Full scale voltage Typical short-circuit current
To 6 M Ω 50 M Ω Typical short-circuit current
1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA,
1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
MA function
Overload protection 44/100 fuse, A, 1000 V, fuse
overload 600 mA overload for up to 2 minutes, at least 10 minutes to a halt
Minimum/maximum record accuracy
Dc function Specify the precision of the measurement function, duration of > 350 milliseconds for counting + 12 times of change.
Communication function Specify the precision of the measurement function, duration of > 900 milliseconds for counting + 40 times of change.
General technical indicators
The highest voltage between any terminal and earthing 1000 V dc or ac RMS
Ω A input fuse protection 0.44 A (44/100 A, 440 mA), 1000 V quick fuse, fluke specified components only
Display (LCD) Update rate 4 / SEC.
The volt, ampere, ohm 6000 times
frequency 10000 times
capacitance 1000 times
The battery type Three AA alkaline batteries, NEDA IEC LR6 15 a
Battery life At least 250 hours
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
The temperature Working temperature - 10 ° C to 50 ° C
Storage temperature To 40 ° to 60 ° C C
The temperature coefficient of 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Relative humidity From 0% to 90% (0 ° C and 35 ° C)
From 0% to 75% (35 ° C to 40 ° C)
From 0% to 45% (40 ° C to 50 ° C)
At an altitude of Work at an altitude of 2000 m
Stored at an altitude of 12000 m
Electromagnetic compatibility
EMI and RFI, EMC (EMC) and RF
EN 61326-1:6, EN 61326-2 - "06
ETSI V1.7.1 EN 300, 328:2006, ETSI EN 300 489
V1.8.1:2008
The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements
FCCID: FCC: T68 - FDMMBLE IC: 6627 a - FDMMBLE
Meet safety standards The ANSI/ISA 61010-1 / (82.02.01) : 3rd edition
CAN/CSA C22.2 No. 61010-1-12:3rd edition
UL 61010-1:3
IEC/EN61010-1:10
certification CSA, the FCC, CE
Protection (IP) rating IP54
Pollution levels 2
Size (height x width x length) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
The weight of the 340 g (12 oz)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

雷竞技appCurrent clamp module Fluke a3000 FC wireless communication

Technical indicators
range 0.5 A and 400.0 A
The resolution of the 0.1 A
precision 400.0 A: 2% + / - 5 (10 Hz to 100 Hz), of 2.5% plus or minus five (100 Hz - 500 Hz)
The surge current According to the biggest readings 999.9 A
Crest factor (50 Hz / 60 Hz) 3 (500 A)
2.5 (600 A)
1.42 (1000 A)
C.F. > 2 increased by 2%
LCD with backlight 3 1/2 level a
Data storage rate/intervals 1 second (minimum)/can be adjusted by the PC
The battery type 15 A, 2 AA, NEDA IEC LR6
Battery life 400 hours
memory Can record up to 65000 readings
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
Working temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
The temperature coefficient of Increased by 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Working humidity 35 ° C in 90%
40 ° C in 75%
50 ° C in 45%
At an altitude of Work at an altitude of 2000 m
Stored at an altitude of 12000 m
Electromagnetic compatibility (EMC) EN 61326-1:6
Meet safety standards IEC 61010-1600 - V class III, third edition pollution level 2
Security level The CAT III 600 V
certification CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE
Protection (IP) rating IP30
Pollution levels 2
Jaw opening The 34 mm (1.33 in)
Size (high x width x deep) 20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in)
The weight of the 0.22 kg (8 oz.)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

雷竞技appFluke t3000 FC wireless module type K temperature

General technical indicators
The range of K type - 200 ° C to 1372 ° C
The resolution of the 0.1 ° c.
precision + / 0.5% + 0.3 ° C
The input terminals K type miniature
W/LCD backlight 3 1/2 level a
Data storage rate/intervals 1 second (minimum)/can be adjusted by the PC
The battery type 15 A, 2 AA, NEDA IEC LR6
Battery life 400 hours
memory Can record up to 65000 readings
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
Working temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
The temperature coefficient of Reading of 0.01% + 0.03 ° C (° C)
Temperature scale ITS - 90.
Working humidity 35 ° C under 90%, 40 ° C under 45%, 50 ° C under 75%
At an altitude of Work at an altitude of 2000 m
Stored at an altitude of 12000 m
Electromagnetic compatibility (EMC) EN 61326-1:6
Meet safety standards IEC 61010-1, in class I, third edition pollution level 2
certification CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE
Protection (IP) rating IP42
Pollution levels 2
Size (high x width x deep) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
The weight of the 0.22 kg (8 oz.)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

Mode雷竞技appl: Fluke 3000 FC HVAC systems

FC HVAC FLK - 3000
雷竞技appFluke 3000 FC HVAC systems

Include:

  • 雷竞技appFluke 3000 FC series wireless multimeter
  • 雷竞技appFluke a 3000 FC wireless college ac current clamp module
  • 雷竞技appFluke 3000 t thermocouple thermometer
  • TL175 test conductor
  • AC175 alligator clip
  • 80 pk - 1 bead K type thermocouple
  • Magnetic hanging belt

Manual + 雷竞技appresources: Fluke 3000 FC HVAC systems