China

雷竞技appFluke 80 series V digital multimeter

  • 雷竞技appFluke 83 v business Responding Industrial Multimeter

The main features

Can make the new function of the productivity
  • Able to accurately measure speed motor drive and other electrical equipment noise voltage and frequency (87 v/C)
  • Built-in thermometer, without other equipment, can easily read the temperature (87 v/C)
  • Optional magnetic suspension kits, convenient setting and observation, hands free to engage in other jobs
  • High brightness of the large digital display screen has two levels of backlight, making 80 V series multimeter measurement results are easier to read than other models

Produc雷竞技appts overview: Fluke 80 series V digital multimeter

Accuracy and diagnostic function can make industrial productivity

New 雷竞技appFluke 87 v/C greatly improve the functions of measurement, diagnosis, resolution and accuracy, able to solve more motor drive, factory automation, power distribution equipment and electrical and mechanical equipment failure.

The new 80 series DMMS include the following models:

  • 雷竞技appFluke 83 V industrial DMMS
  • 雷竞技appTrue RMS Fluke 87 v/C industrial DMMS
  • 雷竞技appFluke 87 v/E2 industrial electrician suite

87 v/C DMMS are very similar to the classic 87 DMMS, but has a stronger ability to solve problems, more secure, convenient and has better impact protection.

80 v series multi-purpose table through a third party independent testing, fully meet the ANSI/ISA S82.01 second edition and CAT EN61010-1 1000 v, 600 v/CAT III IV standard requirements.Can withstand more than 8000 V voltage pulse, which greatly reduces the danger of surge and breakdown.

function 83 v 87 v
Accurately measure true RMS ac voltage and current of nonlinear signal
Optional filter, used to accurately measure the voltage and frequency of the motor drive
Dc accuracy of 0.05%
6000 words, 3-3/4
4-1/2 a precise measurement mode (20000 words)
Measure up to 1000 V ac and dc signals
Continuous measurement for 30 seconds, 20 A, 10 A current
The built-in thermometer, do not need to carry more tools (including the TC probe)
Up to 200 kHz frequency measurement, as well as the percentage of duty ratio
Impedance, on-off and diode testing
10000 (including F capacitance measurement range for capacitance measurement devices and motors
Minimum/maximum - average record, with minimum/maximum alarm functions, can automatically capture signal changes
Peak capture capabilities, can record up to 250 mu s transient signals
Relative mode, when making low impedance measurements can eliminate the interference of the test lead
Automatic and manual range, with greater flexibility
Contact function, capture stable readings, eliminate the noise signal
Large Numbers and two-stage white backlight, enhance the readability
Used in the simulation of the rapid change or unstable signal display pointer
Input alarm function, when using the wrong input plug sound alarm
Improvement of optional sleep mode, extend battery life
To quickly without the need for calibration of seal, replace the battery
With a removable holster "classic" design, a holster can hold the test wire and probe
A lifetime warranty

Electrical safety
All the input level of protection for the Category III, 1000 V and 600 V Category IV.Can take the pulse of more than 8000 V, which greatly reduces the danger of surge and breakdown.

Correct PWM motor drive signal measurement
Before this, no one multi-purpose table can accurately measure speed signal of the motor.How雷竞技appever, Fluke 87 v/C specifically for complex signal generated by the adjustable speed motor drive design.No need to guess driving system fault, will obtain the potential productivity.Each and every measurement is accurate.

  • Pulse width modulation (PWM) ac voltage precise measurement with noise.Can be measured on the ASD and the motor terminal.
  • Accurate measurement frequency (motor speed).frequency测量不受ASD负载频率的影响
  • Using the optional current clamp attachment, alternating current can be measured
  • 87 v/C reading compared with ASD the value shown on
  • Special shielding measures to prevent the drive systems of high frequency, the effects of high-energy noise

Produc雷竞技appt specifications: Fluke 80 series V digital multimeter

Technical indicators
Dc voltage Maximum voltage 1000 V
precision Plus or minus 0.1% (+ 1)
Maximum resolution Including 100 V
Ac voltage Maximum voltage 1000 V
precision Plus or minus 0.5% (+ 2)
Maximum resolution 0.1 mV
Dc current Maximum current 10 A (20. A, the longest 30 seconds)
Accuracy of current Plus or minus 0.4% (+ 2)
Maximum resolution 0.01 mA
Alternating current Maximum current 10 A (20. A, the longest 30 seconds)
Accuracy of current Plus or minus 1.2% (+ 2)
Maximum resolution 0.1 (including A
resistance The biggest resistance 50 M Ω
precision Plus or minus 0.4% (+ 1)
Maximum resolution 0.1 Ω
capacitance The largest capacity 9999 (including F
precision Plus or minus 1% (+ 2)
Maximum resolution 0.01 the nF
frequency Maximum frequency 200 kHz
precision Plus or minus 0.005% (+ 1)
Maximum resolution 0.01 Hz
Duty ratio The biggest duty ratio 99.9%
precision Plus or minus (+ 0.1% / 0.2% kHz)
Maximum resolution 0.1%
conductance The biggest conductance 60.00 nS
precision Plus or minus 1.0% (+ 10)
Maximum resolution 0.01 nS
diode range 3 V
The resolution of the 1 mV
precision Plus or minus 2% (+ 1)
Duty ratio range The accuracy of Within the scope of plus or minus (+ 0.1% / 0.2% kHz)
Environmental indicators
Working temperature - 20 ° C to + 55 ° C
Storage temperature To 40 ° C to + 60 ° C
Humidity (no condensation) 0% - 90% (0 ° C - 35 ° C)
0% - 70% (35 ° C - 55 ° C)
Work at an altitude of 2000 m
Safety specifications
The overvoltage category EN 61010-1 to 1000 V, the CAT CAT III IV 600 V
approval CSA and TUV
The mechanical and general specifications
display digital 6000 count, updated four times per second
simulation 32, update 40 times per second
frequency When counting, 19999 > 10 Hz update 3 times per second
size 201 x 98 x 52 mm (with holster)
The weight of the 355 g
Weight (with holster and flexible frame) 624 g
Warranty period A lifetime
Battery life Alkaline batteries are usually ~ 400 hours, no backlight
impact 1 m high in the fall (according to IEC 61010-1:01)
vibration According to the MIL - PRF - 28800 specification for level 2 meter

Mode雷竞技appl: Fluke 80 series V digital multimeter

雷竞技appFluke 83 v
雷竞技appFluke 83 v business Responding Industrial Multimeter

Include:

  • TL75 test line
  • AC175 alligator clip
  • Protective sleeve
  • 9 v battery (installed)