雷竞技appFluke T + Pro Electrical Tester
The main features
- Detect live voltage, see voltage level, even with the dead batteries
- Three forms of AC/DC voltage indication: light, sound, and vibration
- Backlit LCD display and hold the function for easier viewing
Produc雷竞技appts overview: Fluke T + Pro Electrical Tester
Safer than solenoid testers and fully compliant with NFPA 70 e, (the when informs the properly per Article 110.4, the Use of Equipment (A) the Test Instruments and Equipment), the T + Pro else electricians and technicians work Safer by indicating the presence of voltage, even when the batteries are dead. The Additional functionality, to as A GFCI trip, easy to read LCD screen, hold measurement of up to 9.99 k Ω, and A built - in flashlight make the T + Pro the first voltage tester that electricians reach for.
How to use the 雷竞技appFluke T + Pro Electrical Tester
The 雷竞技appFluke T + Pro Electrical Tester indicated AC/DC voltage in three marketers ways:
Light
Sound
Vibration
The user will be alerted to The presence of voltage in dark or noisy environments have The light and vibration notifications, and The audible indication can be optionally disabled at The push of a button. Combine those features have The backlit LCD display function and it 's easier for users to see The screen in The things hard - to - The test areas. The included HOLD function will freeze The display for even easier reading in those areas.
The Key safety features
The T + Pro is safety rated to CAT IV 600 V, The CAT III 1000 V, and is CSA approved. The tester also has a built - in flashlight for highlighting The point of measurement. A GFCI trip is included for testing outlet GFCI circuits. The T + Pro also includes a rotary field indicator and from The work The probe storage on The back. The product is protected by a two - year giant.
Produc雷竞技appt specifications: Fluke T + Pro Electrical Tester
Specifications | ||
Temperature | Operating | 55 ° to 10 ° C to C (14 ° F to 131 ° F) |
Storage | - 30 ° to 60 ° C (C - 22 ° F to 140 ° F) | |
Relative Humidity | 90% | 0 ° C to 30 ° C (32 ° F to 86 ° F) |
75% | 30 ° C to 40 ° C (86 ° F to 104 ° F) | |
45% | 40 ° C to 50 ° C (104 ° F to 122 ° F) | |
led | Operating | 2000 m (approx. 6561.6 ft) |
Storage | 10000 m (approx. 32808 activity ft) | |
'the Type/Life | AAA (2);40 hours | |
Shock, Vibration | Sinusoidal vibration per MIL - PRF - 28800 - f for a Class 2 instrument | |
Safety | ISA - 82.02.01 Mod (IEC 61010-1), Second Edition, CAN/CSA C22.2 No. 61010-1 Second Edition, IEC 61010-1 III / 600 V to 1000 V CAT CAT IV The Compliance to NFPA 70 e1 |
|
AC Bandwidth | 45 Hz to 66 Hz | |
Maximum Working Voltage | 1000 V AC/DC | |
Maximum Measurable Voltage | 600 V AC/DC | |
Duty Cycle | Indefinitely for voltages of up to 240 V | |
For voltages between 240 V and 600 V, the duty cycle is 30 s 300 s on/off | ||
For voltages above 240 V, the tester must connect to a voltage source only For a MAXIMUM of 30 s and then disconnect For a MINIMUM of 300 s | ||
Voltage Hazard LED | LEDs turn on at voltages > 30 V AC/DC + / - 35% | |
LED Voltage Indication Levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V | |
LEDs | LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100% | |
LCD Accuracy | The AC voltage | Plus or minus 3% (RDG who + 2) |
The DC voltage | Plus or minus 2% (RDG who + 2) | |
To hold | Plus or minus 5% (RDG + 3 who) | |
The LCD Resolution | For 0.1 V voltages < 50 V, 1 V for voltages 50 V or higher | |
0.01 k Ω for hold measurement | ||
GFCI Test Current | 100 V - 150 - V @ 6 mA - 9 mA AC, 150 V - 240 - V < 12 mA | |
Standard Input the Test Current | < 5 mA | |
The Size (H x W x L) | 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm) | |
Weight | 9.9 oz (0.28 kg) | |
1. The When informs the properly per Article 110.9 the Use of Equipment (A) the Test Instruments and Equipment. |
Mode雷竞技appl: Fluke T + Pro Electrical Tester
- The User manual
- The Test lead wrap
- TP2 test the probes