雷竞技appFluke 1730 three-phase electric energy data recorder

  • 雷竞技appFluke 1730 / US Three - Phase Energy Logger
  • 雷竞技appFluke 1730 / US Three - Phase Energy Logger
  • 雷竞技appFluke 1730 Three - Phase Energy Logger. 3
  • 雷竞技appFluke 1730 Three - Phase Energy Logger. 4

The main features

  • The main measures:By understanding the voltage, current, power, power factor and other related values, will help to optimize and implement energy saving scheme.
  • Bright color touch screen: in the graphical display screen can be easily field analysis and data check.
  • Comprehensive records:This device can store more than 20 different records packet session.The recorder is automatically record all measured values, and in the process of recording and download these values before they can view the value for subsequent analysis.
  • To optimize the user interface:Every time according to the instructions shall be carried out in accordance with the graphical steps quickly set up, after all can obtain the correct data;And with the aid of intelligent validation functions can reduce the uncertainty of equipment connection.
  • Through the front panel to complete "the scene Settings:Don't need to return to the office to download and set up, also don't have to carry a computer connected to the distributor.
  • Wider power selection range:Directly get power supply from circuit under test, and don't need to look for a power outlet, and instruments can be securely fixed in power distribution cabinet.
  • Two USB port:A port for PC connection, a different port used to quickly and easily download the data to the standard USB storage or other USB devices.
  • Small size:Designed to adapt to the compact space and narrow distribution cabinets and design.
  • Security:Into the line and load downstream CAT IV use 600 V / 1000 V rated CAT III meet into the line and the downstream use safety level.
  • Optimization of measuring accessories:Flat voltage line-to-line and flexible thin flexible current probe can ensure that users can in close space for installation.
  • Battery life:Use of lithium ion battery, a charge for four hours of operation (spare time).
  • Security:Use the strong and durable Kensington or lock anti-theft lock hole provide security protection for your device.
  • Energy analysis application software:Using automatic reporting functions download the presentation and analysis of potential energy saving potential.And automatically generates the report

Produc雷竞技appts overview: Fluke 1730 three-phase electric energy data recorder

Easily find equipment energy saving opportunities

雷竞技appFluke 1730 three-phase power recorder specially designed for energy saving consciousness of the users, presents a new simple method to help them find the source of electrical energy waste.Analyze the energy use of equipment can help you determine the part of energy conservation, and to provide you with easy to understand the data as a measure of the basis.

Use雷竞技app Fluke 1730, you can:

  • Easily determine the energy consumption of time and location, from line to each of the circuit into the homes of the whole range in the measurement range.
  • Contrast how data points over a period of time, using the energy analysis software package to generate electricity the full story.
  • Can quickly understand the specific loss points, more easily than ever before to reduce energy costs.

In the energy used to per雷竞技appform the investigation and the research of load energy recorder, Fluke 1730 is a good choice.

The energy survey to a new height

If you want to use the energy survey to a new height, so please use 1730 electric energy recorder and the fluke visualization or infrared thermal imager, infrared thermometer at the same time from two aspects of the electrical and thermal fast determine energy saving opportunities.If the infrared thermal imager or visualize combined with 1730 electric energy data recorder using infrared thermometer, you will find potential problems that may cause energy waste and then use the 1730 power quantized energy recorder will these problems.This tool can be found in the process of the equipment operation is not easy to find the waste, such as lighting, air conditioning and other will can be turned off when not used big load device.

Produc雷竞技appt specifications: Fluke 1730 three-phase electric energy data recorder

Precision specifications
parameter range The resolution of the Under the condition of the reference of the basic accuracy + full scale percentage percentage (reading)
voltage 1000 V 0.1 V Plus or minus (0.2% + 0.01%)
current IFlex1500-12 150 A 0.1 A Plus or minus (1% + 0.02%)
1500 A 1 A
IFlex3000-24 300 A 1 A Plus or minus (1% + 0.02%)
3000 A 10 A
IFlex6000-36 600 A 1 A Plus or minus (1.5% + 0.03%)
6000 A 10 A
I40s - EL clamp 4 A 1 mA Plus or minus (0.7% + 0.02%)
40 A 10 mA,
frequency 42.5 Hz - 69 Hz 0.01 Hz Plus or minus (0.1%)
Auxiliary input Plus or minus 10 VDC 0.1 mV Plus or minus (0.2% + 0.02%)
Minimum/maximum voltage 1000 V 0.1 V Plus or minus (1% + 0.1%)
The current minimum/maximum Defined by the attachment Defined by the attachment Plus or minus (5% + 0.2%)
Cos phi/DPF 0 or less Cos phi is 1 or less 0.01 + / - 0.025
The power factor 0 or less PF 1 or less 0.01 + / - 0.025
Voltage THD 1000% 0.1% Plus or minus 2.5% (+ / - 0.05)
Current THD 1000% 0.1% Plus or minus 2.5% (+ / - 0.05)
The inherent uncertainty + + percentage range percentage (reading) creates
parameter Amount of influence IFlex1500-12 IFlex3000-24 IFlex6000-36 I40S - EL
150 A / 1500 A 300 A / 3000 A 600 A / 6000 A 4 A / 40 A
Active power P PF acuity 0.99 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
0.5 < PF < 0.99 1.2% + 7 x (1 - PF) + 0.005% 1.2% + 7 x (1 - PF) + 0.0075% 1.7% + 7 x (1 - PF) + 0.0075% 1.2% + 10 x (1 - PF) + 0.005%
Apparent power S, S fund. 0 or less PF 1 or less 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Reactive power
N, Q fund
0 or less PF 1 or less Has 2.5% of the measurement of apparent power
Range creates additional uncertainty U > 250 V 0.015% 0.0225% 0.0225% 0.015%
1 = 1000 V range Irange x
Reference conditions:
Using the environment: 23 ° C + 5 ° C, instrument for at least 30 minutes of work, no external electrical/magnetic field, RH < 65%
Input conditions: Cos Φ/PF = 1, the sine signal f = 50 Hz / 60 Hz, power 120 V / 230 V + / - 10%
Current and power supply technical indicators: 1 ph: the input voltage of 120 V / 230 V or 3 ph Y/triangle: 230 V / 400 V
10% of the input current: I > Irange
A conductor in the current clamp or the center of the Rogowski coil
Temperature coefficient: above 28 ° C or below 18 ° C, C increased 0.1 times that of the specified precision
Electrical technical indicators
The power supply
Voltage range Use safety input plug by measuring circuit for 100 V to 500 V power supply
When using the standard power cord for 100 V to 240 V (IEC 60320 C7)
Power consumption Maximum 50 VA (using IEC 60320 input when the maximum is 15 VA)
The energy efficiency 68.2% or greater (conform to the specifications of energy efficiency)
Maximum no-load loss < 0.3 W (only when using IEC 60320 input)
The main power supply frequency 50/60 Hz plus or minus 15%
The battery Lithium ion battery 3.7 V, 9.25 Wh (customer can be replaced)
Battery run time Standard operation mode for four hours, up to 5.5 hours power saving mode
Charging time The < 6 hours
The data collection
The resolution of the A 16-bit synchronous sampling
Sampling frequency 5120 Hz
The input signal frequency 50/60 Hz (42.5 to 69 Hz)
Connection mode type 1 - phi, 1 - phi IT, split phase, 3 - phi delta, 3 - phi wye, 3 - phi wye IT, 3 - phi wye balance, 3 - phi Aron/Blondel (two table method), 3 - phi delta open foot, only current (load analysis)
THD Using 25 harmonic calculation of threshold voltage and current
Average period The user can choose 1 second, 5 seconds, 10 seconds, 30 seconds, 1 minute, 5, 10, 15, 30 points
Demand interval The user can choose 5 minutes, 10 minutes, 15 minutes, 20 minutes, 30 minutes
Data is stored Internal flash memory (the user can't change)
Memory capacity Normally stored 10 weeks of 20 recording session, record the time interval of 10 minutes squared
Record cycle (draft) The recommended average period 20 a recording session A recording session
1 second 3 hours, 2.5 days
5 seconds 15 hours 12 days
10 seconds 28 hours 24 days
30 seconds 3.5 days Ten weeks
1 minute 7 days 20 weeks
5 minutes 5 weeks 2 years
Ten minutes Ten weeks More than 2 years
15 minutes 3.5 months More than 2 years
30 minutes 7 months > 2 years squared
interface
USB - A Through the usb file transfer, the firmware update
Maximum current: 120 mA
Use the WiFi adapter need a USB hub with power and with Realtek RTL8188CUS chipset WiFi adapter adapter can be found in the operations manual (recommended)
USB to mini Download the data to the PC
Extend the port accessories
The input voltage
Enter the number of Four (three phase and zero line)
Maximum input voltage 1000 Vrms, CF 1.7
The input impedance 10 M Ω
Bandwidth (3 dB) 2.5 kHz
The zoom 1:1 ¡ ¢10:1 ¡ ¢, 100:1 ¡ ¢1000:1 quarter ° + ה ֱ ¿
Voltage security levels The CAT CAT III 1000 V / 600 V IV
Current input
Enter the number of 3, the automatic selection mode for the connection of sensors
The input voltage Current clamp type: 500 mVrms / 50 mVrms;CF 2.8
Rogowski coil of roche input When 50 Hz 150 mVrms / 15 mVrms, 60 Hz to 180 mVrms / 18 mVrms;Crest factor 4;All in the probe nominal range
range 1 A - 150 - A / 10 A to 1500 A (iFlex flexible current probe), 12 inches
3 A to 300 A/A 30-3000 - A (flexible probe), 24 inches
6 A - 600 - A/A 60-6000 - A (flexible probe), 36 inches
40 mA to 4 A / 0.4 A and 40 A (40 A clamp i40s - EL)
Bandwidth (3 dB) 1.5 kHz
The zoom 1:1, variable
Auxiliary input
Enter the number of 2
The input range 1 to 0 to + 10 V dc, readings per second
The scale factor Format: kx + d (the user can configure)
According to the unit Users can configure (seven characters, such as ° C, psi or m/s)
2. Record the session number and cycle may depend on the needs of users.
Environment specification
Working temperature - 10 ° C to + 50 ° C (14 ° F to 122 ° F)
Storage temperature - 20 ° C to + 60 ° C (4 ° F to 140 ° F)
Working humidity 10 ° to 30 ° C C (50 ° F to 86 ° F) the relative humidity of 9%
30 ° C to 40 ° C (86 ° F to 104 ° F) the relative humidity of 75%
40 ° C to 50 ° C (104 ° F to 122 ° F) the relative humidity of 45%
Work at an altitude of 2000 m ($4000 m when reduced to 1000 V / 600 V II CAT CAT CAT III / 300 V IV)
For altitude 12000 m
The shell IP50 (meet EN60529)
vibration MIL 28800 e, 3 class III, B type
Security level IEC 61010-1: overvoltage CAT IV, measuring the CAT CAT III 1000 V / 600 V IV, the pollution level 2
EMI and RFI, EMC EN 61326-1: industrial grade
Electromagnetic compatibility Only applicable in Korea.Class A equipment (industrial radio and communication equipment)
Radio frequency (rf) to send IEC CISPR 11: Group 1, Class A
The temperature coefficient of Precision index x / 0.1 ° C
General technical specifications
Color LCD display 4.3 inch TFT active matrix, 480 x 272 pixels pixels, resistive touch screens
Warranty period
1730 and power Two years (including battery)
accessories 1 year
Calibration cycle Two years
size
1730 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in)
The power supply 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in)
1730 (power) 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 in)
The weight of the 1730 1.1 kg (2.5 lb)
The power supply 400 g (0.9 lb)
External protection Holster, anti-theft lock slot
Current probe technical specification 1500-12 iFlex activities
Measuring range 1-150 - A 10-1500 - A ac alternating current (ac) /
Current nondestructive 100 kA (50/60 Hz)
The inherent error after reference conditions Readings of plus or minus 0.7%
1730 + iFlex accuracy Plus or minus (1% + 0.02% range readings)
Beyond the working temperature range of temperature coefficient 0.05% of the readings / ° C, 0.09% of the readings / ° F
Working voltage The CAT CAT III 1000 V, 600 V IV
The probe cable length 305 mm (12 in)
The probe cable diameter 7.5 mm (0.3 in)
The minimum bending radius 38 mm (1.5 in)
The output cable length 2 m (6.6 ft)
The weight of the 115 g
The sensor cable material TPR
Connector material POM + ABS/PC
The output cable TPR/PVC
Working temperature Test environment conductor temperature was minus 20 ° C to + 70 ° C (4 ° F to 158 ° F), does not exceed 80 ° C (176 ° F)
Non-work state temperature To 40 ° C to + 80 ° C (to 40 ° F to 176 ° F)
The working status of relative humidity Between 15% and 85% of condensation
The IP rating IEC 60529: IP50
Warranty period 1 year
3. The reference conditions:
Environmental factors: 23 ° C + / - 5 ° C (no external electric field/magnetic field, relative humidity 65%)
A side of the conductor in the centre

Mode雷竞技appl: Fluke 1730 three-phase electric energy data recorder

雷竞技appFluke 1730 / US
雷竞技appFluke 1730 / US Three - Phase Energy Logger

Includes:

  • Includes soft to their case
  • 雷竞技appFluke Energy Analyze software
  • Voltage leads and clips
  • Color localization set
  • The USB interface cable
  • The Power cord
  • Safety sheet
  • USB Flash drive containing application software