China

雷竞技appFluke 43 b power quality analyzer

  • 雷竞技appFluke 43 b Single Phase Power Quality Analyzer
  • 雷竞技appFluke 43 b Single Phase Power Quality Analyzer. 2
  • 雷竞技appFluke 43 b Single Phase Power Quality Analyzer. 3
Has been discontinued

The main features

harmonic

  • Harmonic voltage, current and power
  • Up to 51 times harmonic
  • Total harmonic distortion (THD)
  • The phase Angle of each harmonic

power

  • Watt, power factor and displacement power factor, volt-ampere and spent
  • Voltage and current waveform

three-phase

  • Screen graphics to guide the user how to set up three phase power measurement

Sag and surge

  • After 16 days of time, one by one cycle to continuous measurement of voltage and current
  • Using the cursor read sag and shot up the time and date

The transient phenomena

  • Capture voltage transients and waveform distortion
  • Capture and save as many as 40 transient events
  • Displays the time and date associated with transient

Voltage/amp/hz

  • Voltage and current waveform
  • True RMS voltage and current
  • frequency

This product has been discontinued or reclassified

Produc雷竞技appts overview: Fluke 43 b power quality analyzer

Fully grasp the power quality

Produc雷竞技appt specifications: Fluke 43 b power quality analyzer

Technical specifications
The input parameters The input impedance 1 M Ω, 20 pF
The rated voltage 600 V RMS, CAT III
V/A/Hz True RMS voltage
(ac + dc)
range 5.000 V, 50.00 V, 500.0 V, 1250 V creates
precision Plus or minus 1% (+ 10 counts)
True RMS current
(ac + dc)
range 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA
precision Plus or minus 1% (+ 10 counts)
frequency range 10.0 to 15.0 kHz
precision Plus or minus (reading [%] + [count number]) : 0.5% + 2
CF crest factor range 1.0-10.0
precision (5% + 1 count)
Power display Watt, VA, VAR Single-phase and three-phase three-wire balance load
range 250 W to 1.56 GW
precision Plus or minus 4% (+ 4 count) fundamental wave power
precision Plus or minus 2% (+ 6) total power
PF (power factor) range 0-1.0
precision + / - 0.04
DPF (displacement power factor) range 0.25-0.9
precision + / - 0.04
range 0.90-1.0
precision + / - 0.03
The H2 base wave frequency range 40.0 to 70.0 Hz
precision Plus or minus (reading [%] + [count number]) : 0.5% + 2
Harmonic display Voltage, current and frequency range Fundamental to 51 harmonics
precision VA + + 2 count (3%) W + + 2 count (5%)
Fundamental wave 2 to 31 harmonics VA - counting (5% + 3) W + + 10 counts (10%)
32 to 51 times harmonic Plus or minus 15% (+ 5) to W + (30% + 5 count)
The fundamental frequency range 40 Hz - 70 Hz
precision + / - 0.25 Hz
phase range V, A (fundamental harmonic)
precision Plus or minus 3 ° to plus or minus 15 °
range W (voltage wave of current harmonic)
precision Plus or minus 5 ° to plus or minus 15 °
K coefficient
(current and power)
range 1.0 to 30.0
precision Plus or minus 10%
THD (total harmonic distortion) range 0.00-99.99
precision Counting + + 8 (3%)
Drop and litres Recording time 4 minutes to 16 days (optional)
Actual Vrms, maximum Vrms, minimum (AC + DC) range 5.000 V, 50.00 V, 500.0 V, 1250 V creates
precision Reading + + 10 counts (2%);The cursor readout±(2% + 12 个计数)
Actually very different, very different, the largest minimum (AC + DC) range 50.00 A, 500.0 A, 5.000 kA, 50.00 kA
precision Plus or minus 2% (+ 10 counts)
Transient capture The minimum pulse width 40 ns
Enter 1 useful bandwidth Dc to 1 MHz
The number of transient events 40
Voltage threshold Settings Refer to above or below 20%, 50%, 100%, 200%
Reference signal After the START (START) button, measuring the Vrms and frequency of the signal.According to these data, calculation of pure sine wave as a reference threshold Settings.
The cursor Vpeak minimum, Vpeak maximum 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V accuracy: + / - 5% of full scale
R, C, diode, on and off The resistance range 500.0 Ω Ω Ω, 5.000 k, 50.00 k, 500.0 k Ω Ω, 5.000 M, 30.00 M Ω
Precision of resistance Counting 0.6% plus or minus (+ 5)
Capacitance range NF, 500.0 the nF, 5.000 50.00 mu, 50.00 mu, 500.0 mu F F F
Capacitance accuracy Plus or minus 2% (+ 10 counts)
Diode range 0 to 3.000 V
Diode voltage
precision Counting 2% plus or minus (+ 5)
On and off sex Buzzer open < 30 Ω + 5 Ω
Maximum current 0.5 mA
The temperature ° C or ° F
The surge current Surge time 1 second, 5 seconds, 10 seconds, 50 seconds, 100 seconds, 5 minutes
Current range 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
The cursor readout The cursor to the maximum peak 1 and 2
precision Plus or minus 5% of full scale
Two cursor interval of time Four to 235 pixels (= 1 pixel surge time / 250) accuracy: + / - 0.2% (+ 2 pixels)
The temperature
(including accessories)
range - 100 ° C to 400 ° C
precision Counting 0.5% plus or minus (+ 5)
Oscilloscope display measurement Dc, ac, ac + dc - peak, peak, peak, frequency, duty cycle, phase, pulse width, crest factor
Time range 20 ns/div and 60 s/div
Maximum sampling rate 25 MS/s
bandwidth Voltage channel [1] 20 MHz (in the input), 1 MHz (use TL24 test line)
Current channel [2] Dc to 15 kHz (in the input point), 10 kHz (using i400s current clamp)
coupling Ac and dc (10 Hz - 3 dB)
Vertical sensitivity 500 v / 5 mV/frames
Vertical resolution 8 bit (256)
Record length 512 sampling points/channel
Time base scope 60 S/div to 20 nS/div + + 1 pixel (0.4%)
When the base model Normal, rolling, single
Pre trigger The ten biggest grid
Trigger source Type 1, type 2 or automatic selection
Trigger mode Automatic touch namely test (Connect - and - View ™), Free Run and a single trigger
Connect - and - view ™ Through advanced automatic pattern recognition signal trigger

Automatically adjust the trigger, and amplitude, stable waveform display

memory 20 (for screen, setting, data)
record Recording time 4 minutes to 16 days (optional)
parameter Choose from the following parameter set one or two parameters

Voltage/current/frequency

power Watt, VA, VAR, PF, DPF, frequency

Harmonic and THD, voltage (fundamental wave and harmonic), ampere (fundamental wave and harmonic), w (fundamental wave and harmonic)

Frequency (harmonic), accounting for % of the total (harmonic), phase (harmonic), the K factor

The temperature
resistance Resistor, diode, on and off, capacitance
oscillographic Dc voltage, dc current, ac voltage and ac current, frequency,

Pulse width, phase positive or negative, positive or negative pulse rate, minimum, maximum peak peak, peak, crest factor (minimum - largest)

Environment specification Working temperature 0 ° C to + 50 ° C
Safety specifications Electrical safety EN 61010-1 CAT III, 600 v by CSA certification
Machinery and general technical specifications size 232 x 115 x 50 mm
The weight of the 1.1 kg
Warranty period 3 years
Battery life Rechargeable nickel cadmium battery pack (including battery charger), 6.5 hours longer running time (work)
Shock and vibration MIL 28800 e, 3 class III, B type
The portable box IP51 (dustproof, waterproof, resistance to fall)
1. The security level for EN 61010-1 600 V CAT III CSA

Mode雷竞技appl: Fluke 43 b power quality analyzer

雷竞技appFluke 43 b
雷竞技appFluke 43 b Single Phase Power Quality Analyzer

雷竞技appFluke 43 b includes:

  • C120 scale instrument box
  • TP1 flat Slim - Reach ™ test probe
  • TP4 4 mm round head Slim - Reach ™ Test the Probes
  • I400S alternating current clamp
  • PM - 9080 optical isolation RS232 interface adapter
  • BP120 rechargeable nickel cadmium battery (installed)
  • PM - 8907 power adapter/battery charger
  • SW43W 雷竞技appFluke View ™ power quality analysis software and cd-rom version of the user manual
  • Shielding the banana plug adapter to the BNC
  • User manual/application guide