雷竞技appFluke BT500 series battery internal impedance analyzer
The main features
As the ideal testing tool, it can realize various battery and battery pack for a backup battery application maintenance, fault diagnosis and performance testing
- The main measurements- the battery internal resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and temperature.
- Sequence of measurement model- battery sequence of automatic or manual testing, including voltage, resistance and temperature automatic measurement of storage capability (using BTL21 intelligent test probe), without having to press the button each time needs to be saved the measured value.
- Comprehensive records- all measured values automatically capture in the testing process, and can look up on the instrument after download at any time for analysis.
Produc雷竞技appts overview: Fluke BT500 series battery internal impedance analyzer
Reduce testing complexity, simplify the work flow and intuitive user interface for battery test more simple than ever.
- As the ideal testing tool, it can realize various battery and battery pack for a backup battery application maintenance, fault diagnosis and performance testing
- Intuitive user interface, compact design and solid structure is to achieve good performance, test results and the reliability of the protection
- Has a wide range of battery test functions, including synchronous data acquisition of dc voltage and internal resistance connecting sheet resistance test and the use of integrated interactive handle the infrared temperature measurement system for synchronous measurement temperature
- Dedicated to all types of backup battery measurement.
Threshold voltage and the resistance
Use雷竞技app Fluke battery analyzer, you can quickly and easily define the measurement of the upper and lower threshold or tolerance range.In the process of test, the measured values compared with predefined threshold automatically generated after each measurement "through", "failed" or "warning" instructions.Most can store 10 group threshold, and the determination of threshold indicator depends on the following conditions:
voltage | resistance | |||
> the lower voltage | < voltage limit | The < reference | > reference value and reference value x (1 + warning value %) | > reference value x (1 + failure value) |
through | failure | through | warning | failure |
雷竞技appFluke battery management software
雷竞技appFluke battery management software easy to use, allows you to quickly and easily the data from the battery analyzer imported PC.Measurement data and battery profile information through the store and archive management software, and can be used to switch between comparative result, electrical resistance readings as a result, and trend analysis.Can use all measurement data, battery files easily generate reports and analysis information.
- Quickly see saved readings
- File management
- Provide battery bar graph, and by the end user defined threshold
- Historical trend data of the battery
- Several rounds of discharge voltage
- Quickly generate report
- Fir雷竞技appmware upgrade Fluke battery analyzer
- In the numerical switching between conductance and internal resistance measurements
雷竞技appMobile app Fluke cell analysis
BT521 can also雷竞技app through the analysis of the Fluke battery for mobile applications to transmission of measured data, it provides wireless communication for data download and remote display, (note: Fluke BT521 does not currently compatible with Fluke Connect).Use雷竞技app of Fluke battery analysis of mobile application, you can:
- Browse the file
- Check the sequence of test data
- Email sequence test data
雷竞技appFluke BT510 key features:
- The battery voltage- in the pr雷竞技appocess of internal resistance test, Fluke battery analyzer can also measure the battery voltage being measured.
- Discharge voltage- during discharge or load testing, firing pattern at user defined intervals to collect many voltage of the battery.The user when the battery voltage drops to termination voltage can be calculated by the time required for, and through the calculation of battery capacity loss this time
- Ripple voltage test- measure dc charging circuit and inverter circuit does not require the rectifier voltage of residual communication components.Allows users to test the ac dc component, and find out the root cause of the deterioration of battery performance
- Digital multimeter model and sequence measurement model- digital multimeter model for rapid testing or troubleshooting.In this mode, you can press the battery test order or time series, to preserve and reading.Sequence measurement model for multiple power system and battery maintenance work.Task before you start, the user can configure for the task to a file is used to manage data and generate reports
- Threshold and warningsThreshold - the user can configure up to 10 group, and received after each is finished through/warning/failure
- The connection between the battery resistance test and data management- a resistance measuring the connection between a set of batteries.
- Automatic stay- when you start the automatic save function, if a stable measurement readings 1 second, captures the readings.Then, at the beginning of a new measurement readings to reset
- Automatic measuring save- when you start the automatic measuring preservation, capture an automatic stay after reading will automatically save the measurement readings to the internal storage
- 雷竞技appFluke battery management software- easy to data from the product imported into the PC.Measurement data and battery profile information through the store and archive management software, and can be used for comparison and trend analysis.Can use all measurement data, battery files easily generate reports and analysis information
- Comprehensive records- all measured values automatically capture in the testing process, and can look up on the instrument after download, at any time for analysis
- To optimize the user interface- rapid heuristic Settings to ensure that every time you capture the correct data
- The service life of the battery7.4 V 3000 mAh lithium ion battery can run continuously for more than 8 hours.
- USB port- the data can be quickly downloaded to the attached data analysis and report of management application software.
- Security level- CAT III 600 V, dc 1000 V, apply to all battery power equipment safety measure.
雷竞技appFluke BT520 main characteristics: (used for measuring the battery placed in the battery rack or narrow space)
- In addition to the above included
- BTL20 intelligent test probe group, with a length of the probe and extension rod, and integrate the provide visual and audio feedback of built-in LCD display screen and speaker
- With long and short corner tip probe extender BTL20ANG intelligence test probe group (no temperature sensor)
- With soft package (large)
雷竞技appFluke BT521 main characteristics: (specifically designed for users and needs to include temperature measurement function)
- In addition to the above * also included
- BTL21 intelligent interactive test handle, with a length of the probe and the extension rod, and integrate the provide visual and audio feedback of built-in LCD display and speakers, and each time the test on the battery cathode integrated infrared temperature sensor for temperature measurement
- With long and short corner tip probe extender BTL20ANG intelligence test probe group (no temperature sensor)
- Wireless雷竞技app is suitable for the Fluke battery Mobile application (Fluke BA Mobile) *
- Check the battery analyzer in the graph and the related test results
- Email curve and the test results, the (CSV) data format
* 雷竞技appdon't enclose BTL20 Fluke BT - 521
* it is 雷竞技appnot compatible with Fluke Connect ® application
Produc雷竞技appt specifications: Fluke BT500 series battery internal impedance analyzer
range | The resolution of the | precision | BT510 | BT520 | BT520ANG | BT521 | BT521ANG | |
Battery resistance/connecting sheet resistance1 | 3 m Ω | 0.001 m Ω | 1% + 8 | low | low | low | ||
1% + 68 | low | low | ||||||
30 m Ω | 0.01 m Ω | 0.8% + 6 | low | low | low | |||
0.8% + 12 | low | low | ||||||
300 m Ω | 0.1 m Ω | 0.8% + 6 | low | low | low | low | low | |
3000 m Ω | 1 m Ω | 0.8% + 6 | low | low | low | low | low | |
VDC | 6 V | 0.001 V | 0.09% + 5 | low | low | low | low | low |
60 V | 0.01 V | 0.09% + 5 | low | low | low | low | low | |
600 V | 0.1 V | 0.09% + 5 | low | low | low | low | low | |
1000 V | 1 V | 0.09% + 5 | low | low | ||||
VAC (45 Hz to 500 Hz and 800 Hz filter) | 600 V | 0.1 V | 2% + 10 | low | low | low | low | low |
Frequency (displayed in a VAC and AAC)2 | 500 Hz | 0.1 Hz | 0.5% + 8 | low | low | low | low | low |
Ac voltage ripple (maximum 20 KHz) | 600 mV | 0.1 mV | 3% + 20 | low | low | low | low | low |
6000 mV | 1 mV | 3% + 10 | low | low | low | low | low | |
ADC/AAC (us雷竞技apping the Fluke i410 accessories) | 400 A | 1 A | 3.5% + 2 | low | low | |||
The temperature | 0 ° and 60 ° C C | 1 ° c. | 2 ° C (4 ° F) | low | low | |||
Digital multimeter model | Each with a measurement of time marker gear has 999 records | |||||||
Sequence of measurement model | Can store up to 100 with a timestamp archives and the archives 100 template (each file can store up to 450 cells data) | |||||||
1. The measurement based on ac injection method.Into the source signal is less than 100 mA, 1 kHz. 2. The trigger level VAC: 10 mV, AAC: 10 A |
||||||||
Measurement model | BT510 | BT520 | BT521 | |||||
Ω resistance (m) | low | low | low | |||||
The battery voltage | low | low | low | |||||
Dc voltage | low | low | low | |||||
Ac voltage and frequency (Hz) | low | low | low | |||||
Ripple voltage | low | low | low | |||||
Battery cathode column temperature (using BTL21 straight probe) | low | |||||||
Dc and ac current (and frequency) | low | |||||||
Multimeter model | low | low | low | |||||
Sequence of measurement model | low | low | low | |||||
Discharge voltage measurement | low | low | low | |||||
Automatic measuring save | low | low | low | |||||
Wireless communication | low | |||||||
Check the memory | low | low | low | |||||
General technical indicators - battery analyzer | ||||||||
Size (high x width x deep) | 22 x 10.3 x 5.8 cm (9 x 4 x 2) in | |||||||
The weight of the | 850 g (1.9 lb) | |||||||
The screen size | 7.7 x 5.6 cm (3 x 2.2 in) | |||||||
interface | USB mini | |||||||
The warranty period | 3 years | |||||||
General technical indicators - BTL20ANG corner measuring probe | ||||||||
Long corner detector (overall length) | 242.2 cm (95.38 in) | |||||||
A short corner detector (overall length) | 216.8 cm (85.38 in) | |||||||
Overall span relaxation (coil) | 10.1 cm (4 in) | |||||||
Overall the biggest span (coil) long | 109.2 cm (43) in | |||||||
BTL20ANG Angle probe tip | With horizontal direction into 20 degrees | |||||||
Environmental indicators | ||||||||
Working temperature | 0 ° C to 40 ° C | |||||||
Storage temperature | - 20 ° C to 50 ° C | |||||||
Lithium battery temperature | 0 ° C to 40 ° C | |||||||
Working humidity | The condensation (< 10 ° C) | |||||||
Relative humidity of 80% or less (10 ° to 30 ° C) C | ||||||||
75% RH or less (30 ° C to 40 ° C) | ||||||||
Work at an altitude of | At an altitude of 2000 meters | |||||||
For altitude | 12000 meters above sea level | |||||||
The IP rating | IP40 | |||||||
Light waves, | The FCC grade A | |||||||
Vibration requirement | MIL - PRF - 28800 - f: level 2 | |||||||
Drop test requirements | 1 m drop | |||||||
The temperature coefficient of | Above 28 ° C or below 18 ° C, C increased 0.1 times that of the specified precision | |||||||
Meet safety standards | 600 V CAT III | |||||||
EMC | IEC 61326 | |||||||
ROHS | China and Europe | |||||||
Protection grade 2 | The pollution level II | |||||||
A battery of compliance | UN38.3 | |||||||
UL2054 | ||||||||
IEC62133 | ||||||||
According to the 2 G IEC68-2-26 and 29, 25 G |
Mode雷竞技appl: Fluke BT500 series battery internal impedance analyzer
雷竞技appFluke BT521 advanced battery analyzer
Include:
- Battery analyzer
- 4 line test probe (group)
- BTL10 basic test lead (group)
- Take the adapter TL175 TwistGuard ™ test conductor
- With extended the BTL21 intelligent test of temperature sensor and probe set
- Pliers i410 ac/dc current
- BP500 lithium ion batteries
- BC500 ac charger
- The mini USB cable
- Shoulder strap
- The belt
- Magnetic hanging belt
- 雷竞技appFlukeView ® battery management software
- Portable soft package
- The spare fuse (2)
- The battery label
- Calibration zero ohm resistor
雷竞技appFluke BT520 battery analyzer
Include:
- Battery analyzer
- 4 line test probe (group)
- BTL10 basic test lead (group)
- Take the adapter TL175 TwistGuard ™ test conductor
- Belt extender BTL20 intelligence test probe (no temperature sensor)
- BP500 lithium ion batteries
- BC500 ac charger
- The mini USB cable
- Shoulder strap
- The belt
- Magnetic hanging belt
- 雷竞技appFlukeView ® battery management software
- Portable soft package
- The spare fuse (2)
- The battery label
- Calibration zero ohm resistor
雷竞技appFluke BT510 battery analyzer
Include:
- Battery analyzer
- 4 line test probe (group)
- BTL10 basic test lead (group)
- Take the adapter TL175 TwistGuard ™ test conductor
- BP500 lithium ion batteries
- BC500 ac charger
- The mini USB cable
- Shoulder strap
- The belt
- Magnetic hanging belt
- 雷竞技appFlukeView ® battery management software
- Portable soft package
- The spare fuse (2)
- Calibration zero ohm resistor
雷竞技appFluke BT521ANG advanced battery analyzer
Include:
- Battery analyzer
- 4 line test probe (group)
- BTL10 basic test lead (group)
- Take the adapter TL175 TwistGuard ™ test conductor
- With extender and corner tip BTL20ANG intelligence test probe (no temperature sensor)
- With extended the BTL21 intelligent test of temperature sensor and probe set
- Pliers i410 ac/dc current
- BP500 lithium ion batteries
- BC500 ac charger
- The mini USB cable
- Shoulder strap
- The belt
- Magnetic hanging belt
- 雷竞技appFlukeView ® battery management software
- Portable soft package
- The spare fuse (2)
- The battery label
- Calibration zero ohm resistor
雷竞技appFluke BT520ANG battery analyzer
Include:
- Battery analyzer
- 4 line test probe (group)
- BTL10 basic test lead (group)
- Take the adapter TL175 TwistGuard ™ test conductor
- With extender and corner tip BTL20ANG intelligence test probe (no temperature sensor)
- Belt extender BTL20 intelligence test probe (no temperature sensor)
- BP500 lithium ion batteries
- BC500 ac charger
- The mini USB cable
- Shoulder strap
- The belt
- Magnetic hanging belt
- 雷竞技appFlukeView ® battery management software
- Portable soft package
- The spare fuse (2)
- The battery label
- Calibration zero ohm resistor
Manual + 雷竞技appresources: Fluke BT500 series battery internal impedance analyzer
- BT508 | user manual
- Addendum BT508 | user manual
- BT510 | user manual
- Addendum BT510 | user manual
- BT520 | user manual
- Addendum BT520 | user manual
- BT521 | user manual
- Addendum BT521 | user manual
- BT508 BT510, BT520, BT521 statement | non-volatile memory
- BT508 / BT510 / BT520 / BT521 | quick reference guide
- BT508 / BT510 / BT520 / BT521 | to information security
- BT508 / BT510 / BT520 / BT521 | safety data sheets addendum
- BT500 Shanghai metro case | application cases
- BT500 plant | application cases
- | BT500 battery manufacturing enterprise application cases
- BT500 maintenance | backup battery system application cases
- BT500 unicom station | application cases
- BT500 communications industry | application cases
- BT500 bank data center | application cases
- Backup battery and energy storage battery checking paper | application
- Application case | BT500 Italian railways
- The application case | BT500 online system
- 雷竞技appFluke 500 series battery analyzer using instruction video
- 雷竞技appFluke BT500 series battery internal resistance analyzer instructions: create a report
- 雷竞技appFluke BT500 series battery internal resistance analyzer instructions: create device files
- 雷竞技appFluke BT500 series battery internal resistance analyzer instructions: a quick demonstration
- 雷竞技appSummary of Fluke BT500 series battery internal impedance analyzer
- 雷竞技appFluke BT500 series battery internal resistance analyzer: BTL - 21 probe
- 雷竞技appFluke BT500 series battery internal resistance analyzer: setting the threshold value
- Why do雷竞技app you need a Fluke BT500 series battery internal resistance analyzer