China

雷竞技appFluke 301 a razr clip-on table

  • 301 a 1500 x1000
  • 301 a 1500 x1000 02
  • 301 a 1500 x1000 03
  • 301 a 1500 x1000 04
Sales promotion

The main features

  • Fuselage weighs just 132 g, the thickness of 16 mm, thin and portable pocket
  • 10 mm fine jaw, easily clip into the dense ribbon cable
  • Exchange 400 A range, 0.01 A high resolution
  • Voltage, resistance and on-off test function
  • Current frequency, voltage frequency test function
  • Capacitance, diode test function
The spot
Saleselections475.00
MSRPselections593.00
Save 20%
Tax-inclusive price
Fluke authentic guarantee
With $200 free shipping
Enjoy the return within 7 days

Produc雷竞技appts overview: Fluke 301 a razr clip-on table

Travel light whole

Set out to live, no longer carry heavy tools, will clamp table as a cell phone pocket with you.The test at any time, easily work more efficient.

Intensive jaw to deal

Meet dense platoon line can't card trendy, avoid dangerous operation dial the cable with the hand, the test is more convenient and safe.

Eight of martial arts master

Various basic testing capabilities, and increase the capacitance, diode, current frequency, voltage frequency testing tools, auxiliary judgment more professional.

Fluke 301 blade series fast contrast

parameter 301 a 301 a + 301 b, 301 c 301 d
Alternating current 40.00 A
400.0 A
40.00 A
400.0 A
60.00 A
600.0 A
60.00 A
600.0 A
1000 a
60.00 A
600.0 A
Dc current - - - - 60.00 A
600.0 A
True RMS - - - Square root -
Ac voltage 600.0 V
Dc voltage 600.0 V
resistance 60.00 k Ω
capacitance 999.9 (including F
Voltage and frequency 99.99 kHz
Current frequency 45.0 to 400.0 Hz
On and off Square root Square root Square root Square root Square root
diode Square root Square root Square root Square root Square root
Keeping data Square root Square root Square root Square root Square root
backlight - - Square root Square root Square root
Pens and - Square root Square root Square root Square root
The CAT level The CAT III 300 v
The weight of the 132 g 154 g
size 52 mm x 190 mm x 16 mm
The battery Section 2 AAA
The quality assurance 1 year
Note: F301A + model for F301A TL75 pens and

Produc雷竞技appt specifications: Fluke 301 a razr clip-on table

Product specification
Within one year after the calibration precision, working temperature of 18 ° C to 28 ° C, relative humidity 0% to 75%.Precision specifications using the following form:
+ (% of [reading] + [least significant digit value]).

model 301 A/A + 301 b, 301 c 301 d
Alternating current (45 to 400 Hz) range 40.00 A 400.0 A 60.00 A 600.0 A 60.00 A 600.0 A 1000 a 60.00 A 600.0 A
The resolution of the 0.01 A 0.1 A 0.01 A 0.1 A 0.01 A 0.1 A 1 a 0.01 A 0.1 A
precision 2% + 10 2% + 5 2% + 10 2% + 5 2% + 10 2% + 5 2% + 5 2% + 10 2% + 5
Dc current range - - - 60.00 A 600.0 A
The resolution of the 0.01 A 0.1 A
precision 2% + 10 2% + 5
Ac voltage (45 to 400 Hz) range 600.0 V 600.0 V 600.0 V 600.0 V
The resolution of the 0.1 V 0.1 V 0.1 V 0.1 V
precision 1.5% + 5 1.5% + 5 1.5% + 5 1.5% + 5
Dc voltage range 600.0 V 600.0 V 600.0 V 600.0 V
The resolution of the 0.1 V 0.1 V 0.1 V 0.1 V
precision 1% + 5 1% + 5 1% + 5 1% + 5
resistance range 600.0 Ω
6.000 k Ω
60.00 k Ω
600.0 Ω
6.000 k Ω
60.00 k Ω
600.0 Ω
6.000 k Ω
60.00 k Ω
600.0 Ω
6.000 k Ω
60.00 k Ω
precision 1% + 5 1% + 5 1% + 5 1% + 5
Voltage and frequency range 9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
precision 0.1% + 3 0.1% + 3 0.1% + 3 0.1% + 3
Current frequency range 45.0 to 400.0 Hz 45.0 to 400.0 Hz 45.0 to 400.0 Hz 45.0 to 400.0 Hz
precision 0.1% + 3 0.1% + 3 0.1% + 3 0.1% + 3
capacitance range 9.999 uF 99.99 999.9 uF uF 9.999 uF 99.99 999.9 uF uF 9.999 uF 99.99 uF
999.9 uF
9.999 uF 99.99 999.9 uF uF
precision 2% + 5 5% + 5 2% + 5 5% + 5 2% + 5 5% + 5 2% + 5 5% + 5
diode 3.000 V 3.000 V 3.000 V 3.000 V
10% 10% 10% 10%
True RMS - - low -
On and off low low low low
Keeping data low low low low
backlight - low low low
The CAT level The CAT III 300 v The CAT III 300 v The CAT III 300 v The CAT III 300 v
Body weight 132 g 132 g 132 g 154 g
The fuselage size 52 mm x 190 mm x 16 mm 52 mm x 190 mm x 16 mm 52 mm x 190 mm x 16 mm 52 mm x 190 mm x 16 mm
Jaw opening 34 mm 34 mm 34 mm 34 mm
Clamp arm size 10 mmx10mm 10 mmx10mm 10 mmx10mm 10 mmx10mm
The battery Section 2 AAA Section 2 AAA Section 2 AAA Section 2 AAA
The quality assurance 1 year 1 year 1 year 1 year

General technical indicators

The highest voltage between any terminal and earthing 300 V
V/Ω terminals and the biggest difference between COM terminal voltage 600 V
Display (LCD) 6000 count, update 3 times per second
The battery type 2 AAA, IEC LR03
Battery life Minimum 500 hours
Automatic shutdown time Twenty minutes
The temperature Working temperature: - 10 ° C to 50 ° C;
Storage temperature: - 30 ° to 60 ° C C
Relative humidity Working humidity: the condensation (below 10 ° C);10 ° to 30 ° C C, relative humidity of 90% or less;30 ° C to 40 ° C, the relative humidity of 75% or less.40 ° C to 50 ° C, the relative humidity of 45% or less;
At an altitude of Work: the elevation 2000 m;Storage: 12000 m
The temperature coefficient of 0.1 X (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Volume (high x width x length) 52 mm x 190 mm x 16 mm
The weight of the 132 g (154 g) 301 d
Jaw opening 34 mm
The IP rating IP30
security IEC61010, IEC 61010-1-2-032 CAT III 300 V, pollution level 2
Electromagnetic environment IEC 61326-1: portable

Mode雷竞技appls: Fluke 301 a razr clip-on table

雷竞技app301 a Fluke,

Mode雷竞技appls: Fluke 301 a razr clip-on table

雷竞技app301 a Fluke,

  • 雷竞技appFluke 301 a clip-on table
  • Section 2 AAA batteries

雷竞技appFluke 301 a +

  • 雷竞技appFluke 301 a clip-on table
  • TL75 pens and
  • Section 2 AAA batteries

No雷竞技appte: no pens and Fluke 301 a standard, Fluke 301 a + model for Fluke301A plus a TL75 pens and