雷竞技appFluke 378 fc harmonic and screening clamp table of energy efficiency
The main features
- Jaw is used to measure the voltage and current;
- Testing faster, more secure, using FieldSense ™ technology without having to touch electric wire;
- Power quality indicator display device or the power cord is defective;
- Fewer steps to complete the test three-phase voltage and current.
Produc雷竞技appts overview: Fluke 378 fc harmonic and screening clamp table of energy efficiency
Using FieldSense ™ technology, measure the voltage and current
雷竞技appFluke 378 FC true RMS clamp table adopts FieldSense ™ technology, make the test more quickly and safety, without contact with the charged conductor.Through jaw obtain accurate measurements of voltage and current.Just put the black test lead clip on any electrical grounding, then jaw clips a conductor, can see on the screen is reliable, accurate voltage and current value.
Power quality indicator can display device or the power cord whether there is any problem
378 FC clamp table has a unique function of PQ, can automatically detect the power quality problems.FieldSense measurement, 378 FC will detect and display with the current, voltage, power factor, or any combination of these three related to power quality problems.Can quickly determine the upstream supply side issues, or downstream equipment problems.
Quick easy to complete the three phase measurement
- Just three simple steps to complete test three-phase voltage and current
- A full set of relative and relative phase was calculated
- Display on sm雷竞技appart phones, and through the Fluke Connect the software to the cloud
- To calcula雷竞技appte the phase sequence and displayed in the Fluke Connect software
- No handwritten notes or complex calculations.
Using iFlex ® probe measuring high current
Through the attached iFlex flexible current probes, you can measure up to 2500 A alternating current.Using iFlex probe can easily measure the crowded wiring ark and large conductors.
Use the attached tool to view and use easily
Use 378 FC clamp table, make the job easier.The detected stable FieldSense measurements, the display turns green.Light green screen, Visual Continuity is also provided to detect noisy electrical Continuity in the work area.
Use雷竞技app FlukeConnect ® software to record, analyze, and share the results
Use雷竞技app Fluke Connect software, you can be the result of the measurement for remote record, trend analysis and monitoring, to find out the intermittent failures.Thr雷竞技appough the Fluke Connect, will also be able to collect data as the basis of preventive maintenance plan.
Packing list
雷竞技appFluke 378 FC current clamp table includes:
- 雷竞技appFluke 378 FC true RMS non-contact voltage clamp table
- IFlex flexible current probe (18 inches;48 cm)
- TL224 silica insulation test conductor
- TP175 test probe length can be adjusted
- AC285 grounding clip (a) black,
- TPAK magnetic pendant with 9 inches (23 cm) hanging belt
- The suitcase
- Quick reference guide
Produc雷竞技appt specifications: Fluke 378 fc harmonic and screening clamp table of energy efficiency
General technical indicators | ||
The highest voltage between any terminal and earthing | 1000 V | |
The battery | type | 2 AA IEC LR6 alkaline |
life | 200 hours | |
display | The double reading | |
Automatic shutdown | Twenty minutes |
electrical | ||||
Alternating current: through the jaw | ||||
range | 999.9 A | |||
The resolution of the | 0.1 A | |||
precision | 2% plus or minus five (45 Hz - 66 Hz) | |||
Crest factor (50/60 Hz) | 500 A is 3 Under the 600 A was 2.5 Under the 1000 A was 1.42 Increased by 2% (C.F.) > 2 |
|||
Alternating current: through flexible current probe | ||||
range | 2500 A | |||
The resolution of the | 1 A (2500 A) or less 0.1 A (A) 999.9 or less | |||
precision | 3% plus or minus five (5 Hz - 500 Hz) | |||
Crest factor (50/60 hz) | When the 1100 A is 3.0, 2.5 when the 1400 A 1.42, 2500 A, Increased by 2% (C.F. > 2 |
|||
Position the sensitivity | ||||
The best distance | I2500-10 Flex | I2500-18 Flex | error | |
a. | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | Plus or minus 0.5% | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | Plus or minus 1.0% | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | Plus or minus 2.0% | |
Measurement uncertainties of centering on holiday main lead in the best position, without external electric or magnetic fields and in the operating temperature range. | ||||
Dc current | ||||
range | 999.9 A | |||
The resolution of the | 0.1 A | |||
precision | 2% plus or minus five1 | |||
[1]Using ZERO function to compensate the deviation | ||||
Ac voltage: Field Sense | ||||
range | 1000 V | |||
The resolution of the | 1 V, 1000 V or less) | |||
precision | 4/0 AWG or less | 3% plus or minus five (45 Hz - 66 Hz) | ||
4/0 AWG or higher | 5% plus or minus five (45 Hz - 66 Hz) | |||
Will wire as much as possible in a location near the jaw opening (see chart). | ||||
Ac voltage: by test conductor | ||||
range | 600.0 V to 1000 V | |||
The resolution of the | 0.1 V, 600.0 V or less) 1 V, 1000 V or less) |
|||
precision | 1% plus or minus five (20 Hz - 500 Hz) | |||
Dc voltage | ||||
range | 600.0 V 1000 V |
|||
The resolution of the | 0.1 V, 600.0 V or less) 1 V, 1000 V or less) |
|||
precision | 1% plus or minus five | |||
Dc millivolt | ||||
range | 500.0 mV | |||
The resolution of the | 0.1 mV | |||
precision | 1% plus or minus five | |||
Amps frequency: the jaw | ||||
range | 45 Hz - 66 Hz | |||
The resolution of the | 0.1 Hz | |||
precision | 0.5% plus or minus five | |||
Trigger level | 5 Hz to 10 Hz, 10 or higher A A 10 Hz to 100 Hz, 5 A or more 100 Hz and 500 Hz, 10 or higher A |
|||
Amps frequency: through flexible current probe | ||||
range | 5.0 Hz to 500.0 Hz | |||
The resolution of the | 0.1 Hz | |||
precision | 0.5% plus or minus five | |||
Trigger level | 5 Hz and 20 Hz, or 25 A 20 Hz - 100 Hz, 20 or more A 100 Hz and 500 Hz, or 25 A |
|||
resistance | ||||
range | 60.00 k Ω 6000 Ω 600.0 Ω |
|||
The resolution of the | 600.0 Ω 0.1 Ω (or less) 6000 Ω 1 Ω (or less) 10 Ω (60.00 k or less Ω) |
|||
precision | 1% plus or minus five | |||
capacitance | ||||
range | 1000 mu F | |||
The resolution of the | 0.1 u F (100.0 u F or less) 1 u F (1000 mu F or less) |
|||
precision | 1% plus or minus four | |||
Mechanical indicators | ||||
Size (length x width x height) | 47 mm x 274 mm x 86 mm | |||
Weight (with battery) | 463 g | |||
Jaw opening | 34 mm | |||
Flexible current probe diameter | The 7.5 mm | |||
Flexible current sensor cable length (top to electronic connector) | 1.8 m | |||
Roche stitch length | 450 mm | |||
Environmental requirements | ||||
Working temperature | - 10 ° C to 50 ° C | |||
Storage temperature | To 40 ° to 60 ° C C | |||
Working humidity (no condensation) | No condensation (< 10 ° C) Relative humidity of 90% or less (10 ° to 30 ° C) C The relative humidity of 75% or less (30 ° C to 40 ° C) Relative humidity of 45% or less (40 ° C to 50 ° C) |
|||
The temperature coefficient of | Above 28 ° C or below 18 ° C, every C increased 0.1 times that of the specified precision | |||
Protection grade | IEC 60529: IP30 (jaw closed) | |||
Work at an altitude of | 2000 m | |||
For altitude | 12 000 m | |||
Electromagnetic compatibility (EMC) | ||||
The international standard | IEC 61326-1: portable electromagnetic environment IEC 61326-2-2, CISPR 11: group 1 B class |
|||
Group 1: equipment to produce and/or the use of conductive coupling radio frequency energy, it is necessary for internal operation with the device itself. | ||||
Class B: such equipment is suitable for household facilities as well as directly connected low-voltage power supply network facilities. Connect the device to the test object, may appear more than CISPR 11 levels of emission. |
||||
South Korea's (KCC) | Class A equipment (industrial radio and communication equipment) | |||
Class A: such equipment conforms to the requirement of industrial equipment electromagnetic waves, distributor or user should pay attention to this.This equipment is intended for the business environment, rather than the home environment. | ||||
The United States (FCC) | 47 CFR part 15 B child.According to the provisions of article 15.103 of this product is regarded as saving equipment. | |||
security | ||||
General information | IEC 61010-1: pollution level 2 | |||
measurement | IEC 61010-2-032:1000 V / 600 V IV CAT CAT III IEC 61010-2-033:1000 V / 600 V IV CAT CAT III |
|||
Current clamp table for leakage current measurement | IEC 61557 - lift type, 30 A/m or less | |||
radio | ||||
Radio certification | The FCC ID: T68 - FBLE IC: 6627 a - FBLE | |||
Frequency range | 2405 MHz to 2480 MHz | |||
The output power | < 100 mW | |||
Radio frequency data | Radio Frequency Data For Class A Devices Simplified version of the eu compliance declarations 雷竞技appFluke declare that the product contained in the radio equipment in accordance with directive 2014/53 / EU.If you need to view the full contents of conformance statement, please visit the following url:https://dam-assets.雷竞技appfluke.com/s3fs-public/FLK_RED_1aeng0900.pdf. |
Mode雷竞技appl: Fluke 378 fc harmonic and screening clamp table of energy efficiency
Include:
- 雷竞技appFluke 378 FC true RMS non-contact ac/dc voltage clamp table
- TL224 test conductor
- TP175 TwistGuard ™ test probe
- AC285 black clamp (1)
- I2500-18 iFlex ® flexible current probe is 18 inches (48 cm)
- TPAK ToolPak ™ magnetic instrument hanging belt
- High quality suitcase
- Quick reference guide
Manual + 雷竞技appresources: Fluke 378 fc harmonic and screening clamp table of energy efficiency
- 雷竞技app377 FC, Fluke Fluke 378 FC | user manual
- FC 377, 377, 378, 378 FC | calibration manual
- 雷竞技app377 FC, Fluke Fluke 378 FC | product technical indicators
- 雷竞技app377 FC, Fluke Fluke 378 FC statement | non-volatile memory
- 雷竞技app377 FC, Fluke Fluke 378 FC | quick reference guide
- 雷竞技app377 FC, Fluke Fluke 378 FC | to information security
- Radio Frequency Data Class A | instructions page