雷竞技appFluke 324 true RMS clamp type table
The main features
"It can meet the demand of all HVAC or maintenance technicians.A dozen of my colleagues, there are nine people with 324 "- Thomas said
- Solid and reliable basic true RMS clamp type table
- Measured 400 A ac current, 600 v ac/dc voltage
- Measurable 4 k Ω resistance, on-off testing 30 Ω or less
- 323 type pliers table features added: temperature, capacitance, backlighting
selections1637.00
Produc雷竞技appts overview: Fluke 324 true RMS clamp type table
雷竞技appFluke 324 true RMS clamp type table is suitable for commercial and residential electrician, is a reliable, robust fault diagnosis and eliminate tool, true RMS measurement function, easy to transport and use of fine design, as well as the wide screen, fault diagnosis can be efficient and ruled out.Increasing temperature and capacitance function, can meet the demand of all HVAC technicians.
Safe and accurate diagnosis and troubleshooting
Standard:
Safe and accurate diagnosis and troubleshooting
- CAT, CAT III 600 V IV the 300 V safety level
- To provide true RMS ac voltage and current measurements, accurate measurement of nonlinear signal
- Measured 400 A alternating current
- Measured 600 v ac/dc voltage
- Measurable 4 k Ω resistance, on-off testing 30 Ω or less
- Measurable - 10 ° C to 400 ° C temperature range
- It can measure 1000 mu F capacitance
- Backlight and maintaining function, the capture screen displayed on the readings
- Provide a two-year warranty, standard soft carrying bag
雷竞技appFluke 323 true RMS clamp type table | 雷竞技appFluke 324 true RMS clamp type table | 雷竞技appFluke 325 true RMS clamp type table | |
Alternating current | 400 a | 40 a / 400 a | 40 a / 400 a |
DC a. | 40 a / 400 a | ||
Ac/dc voltage | 600 v | 600 v | 600 v |
resistance | 400 Ω Ω / 4 k | 400 Ω Ω / 4 k | 400 Ω Ω / 40 k / 4 k Ω |
On and off sex | 70 or less Ω | 30 or less Ω | 30 or less Ω |
capacitance | 100 mu F / 1000 u F | 100 mu F / 1000 u F | |
The temperature | - 10 ° C to 400 ° C | - 10 ° C to 400 ° C | |
backlight | There are | There are | |
frequency | 5 hz - 500 hz | ||
Minimum/maximum | There are |
Standard:
- 雷竞技appFluke 324 true RMS clamp type table
- TL75 test line
- K type thermocouple
- Section 2 AAA batteries (installed)
- Soft with package
Produc雷竞技appt specifications: Fluke 324 true RMS clamp type table
Technical indicators | ||
Alternating current | range | 40.00 A / 400.0 A |
The accuracy of | 1.5% plus or minus five words (45 Hz - 400 Hz) Note: a 2% increase in @ sensitivity in position |
|
Dc current | range | - |
The accuracy of | - | |
Ac voltage | range | 600.0 V |
precision | 1.5% plus or minus five words | |
Dc voltage | range | 600.0 V |
precision | 1.0% plus or minus five words | |
resistance | range | 400.0 Ω Ω / 4000 |
The accuracy of | 1.0% plus or minus five words | |
On and off sex | 30 or less Ω | |
capacitance | 0 to 100.0 u F / 100 mu to 1000 mu F F | |
frequency | - | |
Ac response | True RMS | |
backlight | There are | |
Keeping data | There are | |
Contact temperature | 10.0 ° and 400.0 ° C C (14.0 ° F to 752.0 ° F) | |
Minimum/maximum | - | |
size | H x W x D (mm) | 207 x 75 x 34 |
The largest wire diameter | 30 mm (MCM) 600 | |
The weight of the | 208 g | |
Specified level | The CAT III 600 V The CAT IV 300 V |
|
Low pass filter parameters | Has built-in, 800 hz | |
The quality assurance | 2 years |
Mode雷竞技appls: Fluke 324 true RMS clamp type table
雷竞技appFluke 324
雷竞技appFluke 324 true RMS clamp type table
- 雷竞技appFluke 324 true RMS clamp type table
- TL75 test line
- K type thermocouple
- Section 2 AAA batteries (installed)
- Soft with package