雷竞技appFluke 325 true RMS clamp type table
The main features
- Solid and reliable true RMS clamp type table, with functions of dc current and frequency measurements
- Is 400 A ac and dc current measurement
- To 600 V ac and dc voltage measurement
- To provide true RMS ac voltage and current measurements, accurate measurement of nonlinear signal
- Using the on off sex detection, but 4 k Ω resistance measurement
- The measured frequency of 500 Hz
Produc雷竞技appts overview: Fluke 325 true RMS clamp type table
雷竞技appFluke 325True RMS clip-on table small size, but with a strong communication/Dc power
雷竞技appFluke 325 type pliers table is 320 series pliers type table top with equipment.Designed for bad environment, can provide reliable result without noise, thus completely trustworthy, can help you confidently diagnose all kinds of electrical fault.Have true RMS measurement function, through optimization of human body engineering design, wide backlit display screen and strong compact design, very suitable for narrow indoor cable up to 400 A current measurement.You can also use it to measure temperature, capacitor, ac/dc current and frequency.Commercial and residential electrician can use 325 to test load current, voltage and circuit, switch, fuse and the on-off of the contact.Using frequency measurement function, can check portable generator;Dc current test backup battery and solar energy storage devices.
雷竞技appFluke 325 offers a two-year warranty, standard soft carrying bag.
Other useful features:
- Provide minimum/maximum functionality
- Measuring temperature, 10.0 ° C to 400.0 ° C (14.0 ° and 752.0 ° F) F
- Large, easy-to-read backlit display shows the measured values
- Measuring 1000 (including F capacitance
- Keep the function, the capture screen displayed on the readings
- CAT, CAT III 600 V IV the 300 V safety level
雷竞技appFluke 323 true RMS clamp type table | 雷竞技appFluke 324 true RMS clamp type table | 雷竞技appFluke 325 true RMS clamp type table | |
Alternating current | 400 a | 40 a / 400 a | 40 a / 400 a |
DC a. | 40 a / 400 a | ||
Ac/dc voltage | 600 v | 600 v | 600 v |
resistance | 400 Ω Ω / 4 k | 400 Ω Ω / 4 k | 400 Ω Ω / 40 k / 4 k Ω |
On and off sex | 70 or less Ω | 30 or less Ω | 30 or less Ω |
capacitance | 100 mu F / 1000 u F | 100 mu F / 1000 u F | |
The temperature | - 10 ° C to 400 ° C | - 10 ° C to 400 ° C | |
backlight | There are | There are | |
frequency | 5 hz - 500 hz | ||
Minimum/maximum | There are |
Can simultaneously test voltage/current converter clamp table: fluke ember ACD - 14 - PRO
Produc雷竞技appt specifications: Fluke 325 true RMS clamp type table
Technical indicators | ||
Alternating current | range | 40.00 A / 400.0 A |
The accuracy of | 2% plus or minus five words (45 Hz - 65 Hz) 2.5% plus or minus five word (65 Hz - 400 Hz) |
|
Dc current | range | 40.00 A / 400.0 A |
The accuracy of | 2% plus or minus five words | |
Ac voltage | range | 600.0 V |
The accuracy of | 1.5% plus or minus five words | |
Dc voltage | range | 600.0 V |
The accuracy of | 1.0% plus or minus five words | |
resistance | range | 400.0 Ω Ω / 4000 Ω / 40.00 k |
The accuracy of | 1.0% plus or minus five words | |
On and off sex | 30 or less Ω | |
capacitance | 0 to 100.0 u F / 100 mu to 1000 mu F F | |
frequency | 5.0 Hz to 500.0 Hz | |
Ac response | True RMS | |
backlight | There are | |
Keeping data | There are | |
Contact temperature | 10.0 ° and 400.0 ° C C (14.0 ° F to 752.0 ° F) | |
Minimum/maximum | There are | |
size | H x W x D (mm) | 207 x 75 x 34 |
The largest wire diameter | 30 mm (MCM) 600 | |
The weight of the | 283 g | |
Specified level | The CAT III 600 V The CAT IV 300 V |
|
Low pass filter parameters | Has built-in, 800 hz | |
The quality assurance | 2 years |
Mode雷竞技appls: Fluke 325 true RMS clamp type table
Includes:
- 雷竞技appFluke 325 True RMS Clamp Meter
- TL75 Test Leads
- Type K Thermocouple
- Two AAA Batteries (Installed)
- Soft Case