China

雷竞技appFluke 373 true RMS ac clip-on (type) table | clip-on ammeter

  • 雷竞技appFluke 373 True RMS AC Clamp Meter
  • 雷竞技appFluke 373 True RMS AC Clamp Meter
  • 雷竞技appFluke 373 True RMS AC Clamp Meter
  • 雷竞技appFluke 373 True RMS AC Clamp Meter

The main features

  • Using fixed clamp for 600 A ac current measurements
  • 600 V ac/dc voltage measurement
  • Through the signal processing of the new technology, can be used in the high electrical noise environment, at the same time provide a stable reading
  • The CAT IV 300 V, the CAT III 600 V
  • Clip-on ammeter true RMS ac voltage and current measurements, can be precisely measure the nonlinear signal
  • Large, backlit display screen is easy to read, can automatically set the correct range, so don't need to change the switch position measurement
  • 3 years warranty
  • Soft carrying bag
The spot
selections1822.00
Tax-inclusive price
Fluke authentic guarantee
With $200 free shipping
Enjoy the return within 7 days

Produc雷竞技appts overview: Fluke 373 true RMS ac clip-on (type) table | clip-on ammeter

All measurement at any time.New雷竞技app Fluke 373 true RMS clamp table provides higher performance, very suitable for measuring alternating current only.At the same time, it also can measure true RMS ac v雷竞技appoltage and current, and with a continuity test function, carries out up to 6000 Ω resistance measurement, therefore, Fluke 373 clip-on ammeter provides you need all the measurement function.

Meet the following safety standards
EN/IEC 61010-1:01;The CAT CAT III 600 v, 300 v IV

Produc雷竞技appt specifications: Fluke 373 true RMS ac clip-on (type) table | clip-on ammeter

Electrical technical specifications
Alternating current (ac)
range 600.0 A
The resolution of the 0.1 A
precision 2% plus or minus five (48-62 Hz)
Crest factor (50/60 Hz) 2.5 (600 A)
Ac voltage
range 600.0 V
The resolution of the 0.1 V
precision 1.0% plus or minus five (48-62 Hz)
Dc voltage
range 600.0 V
The resolution of the 0.1 V
precision 1% plus or minus five
resistance
range 600.0 Ω Ω / 6000
The resolution of the 0.1 Ω Ω / 1
precision 1% plus or minus five
On-off test buzzer 30 Ω
capacitance
range 10.0 100.0 u F / 1000 u F
The resolution of the 0.1 u F u F / 1
precision 1.9% plus or minus two
Mechanical specifications
Size (length x width x height) 232 mm x 85 mm x 45 mm
The weight of the 370 g
Environmental indicators
Working temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
Working humidity The condensation (< 10 ° C)
90% RH or less (10 ° to 30 ° C) C
75% RH or less (30 ° C to 40 ° C)
45% RH or less (40 ° C to 50 ° C)
(condensate)
Work at an altitude of 3000 meters
For altitude 12000 meters
EMI and EMC Meet EN61326 - and all the related requirements in 06
The temperature coefficient of More than 28 ° C, below 18 ° C, each with 0.1 x regulation accuracy
Meet safety standards The ANSI/ISA S82.02.01:2004
CAN/CSA - C22.2 no. 61010-1-4
IEC/EN 61010-1:01, 600 v and 300 v CAT CAT III IV
Pollution level 2
EN/IEC 61010-2 - moreover, 02
EN/IEC 61010-031:2002 / A1:2008
Accredited institution
The battery 15 a, 2 AA, NEDA IEC LR6

Mode雷竞技appl: Fluke 373 true RMS ac clip-on (type) table | clip-on ammeter

雷竞技appFluke 373

True RMS ac clamp type table/clip-on ammeter

Enclosed is the attachment:

  • Coating instructions
  • Safety information that
  • Soft carrying bag
  • TL75 test line
  • Type 5 AA alkaline batteries