雷竞技appFluke 718 series pressure calibrator | pressure check
The main features
- Pressure check pressure source and ma, can almost all pressure equipment calibration and maintenance
- Accidental exposure to liquid, the built-in pump extremely easy cleaning, and thus reduce the total cost of ownership and maintenance cost, at the same time also allows the maintenance of the pump at the scene of the work
- Pressure verification error rate calculation function allows staff at the scene of the work pass/fail decision can be quickly
- Milliampere accuracy (0.015%), reassuring measurements and a wider range of workload
- Minimum/maximum/keep function easily capture the measured value of the constantly changing
- Switch test functionality allows faster and more accurately tested pressure switch
- New 7 kpa and 2.1 MPa pressure range means in the field of calibration and maintenance requires less additional tools
- 7 kpa pressure checking instrument can now provide, 200 kpa, 700 kpa and 2100 kpa module built-in pressure range
Produc雷竞技appts overview: Fluke 718 series pressure calibrator | pressure check
Pressure calibration of integrated solutions
雷竞技appFluke 718 series pressure calibrator/verification (including 4 types) is designed for transmitter, instruments and switch to build integrated pressure calibration solution.This kind of pressure calibration solution is exquisite compact size and only one-third of similar instrument, and the weight is only 1 kg (2 lb).Pressure verification独特的易清洗泵不仅有助于保护泵不受损坏,同时还拥有免拆卸的维修特性,即便在工作现场也是如此。
View: total pressure calibration solution, all the problem solved
Produc雷竞技appt specifications: Fluke 718 series pressure calibrator | pressure check
Technical specifications | |
雷竞技appFluke 718 series | |
Measuring the pressure | (internal sensor) |
precision | 0.05% of full scale |
function | To zero, the minimum/maximum, maintain and damping |
Drying, non corrosive air only | |
雷竞技appFluke 718 1 g | |
range | 1 psi to + 1 psi (6.89 kPa to 6.89 kPa) |
The resolution of the | 0.0001 psi, 0.0001 kPa |
overpressure | 5 x full scale |
function | Zero, minimum, maximum, maintain and damping |
雷竞技appFluke 718 30 g | |
range | - 12 psi to 30 psi (85 to 206.84 kPa) |
The resolution of the | 0.001 psi, 0.01 kPa |
overpressure | 5 x full scale |
function | Zero, minimum, maximum, maintain and damping |
雷竞技appFluke 718 100 g | |
range | - 12 psi to 100 psi (85 kPa) 689.48 |
The resolution of the | 0.01 psi, 0.01 kPa |
overpressure | 2 x full scale |
function | Zero, minimum, maximum, maintain and damping |
雷竞技appFluke 718 300 g | |
range | - 12 psi to 300 psi (83 to 2068 kPa) |
The resolution of the | 0.01 psi, 0.1 kPa |
overpressure | 375 psi, 25 bar |
function | Zero, minimum, maximum, maintain and damping |
With 700 series雷竞技app pressure module Fluke 718 series | |
range | 29 pressure module, the calibration range from 0 to 1 inH20 to 10000 psi.Overvoltage protection in line with the pressure module specification |
The resolution of the | In line with the pressure module index |
precision | Up to 0.025% full, in line with the pressure module specification |
function | Zero, minimum, maximum, maintain and damping |
Technical specifications conform to conform to the pressure medium compatibility module | |
Using t雷竞技apphe built-in pump Fluke 718 series | |
range | - 12 psi to full support pressure units: psi, inH20 (4 ° C), inH20 (20 ° C), cmH20 (4 ° C), cmH20 (20 ° C), bar, kPa, inHg, mmHg, kg/cm |
Circuit power | 24 V dc |
precision | Plus or minus 10% |
Drive;> 6.8 V battery to 20 mA, 1000 Ω;5.8 to 6.8 V battery for 700 Ω | |
MA measurement | |
range | 0 mA mA to 24 |
The resolution of the | 0.001 mA |
precision | Count 0.015% + 1 times |
General technical specifications | |
Maximum voltage | 30 v (not operation) |
The temperature | To 40 ° to 60 ° C C |
Working temperature | - 10 ° C to 55 ° C |
Relative humidity | 95% (10 ° to 30 ° C C);75% (30 ° C to 40 ° C).45% (40 ° C to 50 ° C).35% (50 ° C to 55 ° C) |
Work at an altitude of | 3000 metres (maximum) |
impact | 1 m drop test |
vibration | Random, 2 g, 5 Hz - 500 Hz |
Security level | CAN/CSA C22.2 No. 1010.1, 1992 |
Electromagnetic compatibility (EMC) | EN50082-1:1992 and EN55022:1994 Class B |
size | 216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in) |
The weight of the | 35 oz (992 g) |
Electricity, battery life: | 9 v ANSI/NEDA 1604 a or IEC 6 lr619v alkaline batteries;The 718 series with two batteries |
Battery life | 4 to 20 hours (typical), depending on the function |
Warranty period | Pre雷竞技appssure pump warranty of three years (Fluke 718 a year) |
display | LCD display, 5 digits, pressure and current synchronous display |
Suitable for measuring the corrosive gas |
Mode雷竞技appl: Fluke 718 series pressure calibrator | pressure check
Pressure verification - 1 to 1 PSI (6.89 to 6.89 k Pa) -
All models include:
- The yellow sheath with test line storage function
- Manual (14 languages)
- Test line and alligator clip
- Two 9 v alkaline battery
PSI pressure calibrator to 12 to 30 PSI (206.84 kPa) - 85 -
Contains:
- The yellow sheath with test line storage function
- Manual (14 languages)
- Test line and alligator clip
- Two 9 v alkaline battery
- NIST - traceable calibration reports and data
PSI pressure calibrator - 12 to 100 PSI (689.48 kPa) - 85 -
Contains:
- The yellow sheath with test line storage function
- Manual (14 languages)
- Test line and alligator clip
- Two 9 v alkaline battery
- NIST - traceable calibration reports and data
PSI pressure calibrator - 12 to 300 PSI (83 to 2068 kPa)
Contains:
- The yellow sheath with test line storage function
- Manual (14 languages)
- Test line and alligator clip
- Two 9 v alkaline battery
- NIST - traceable calibration reports and data
Manual + 雷竞技appresource: Fluke 718 series pressure calibrator | pressure check
- 718 | user manual
- 718 | user manual addendum
- 712 | instructions page
- Page 712 | show addendum
- 714 | instructions page
- Page 714 | show addendum
- 715 | instructions page
- Page 715 | show addendum
- 715 | non-volatile memory
- 717 | instructions page
- Page 717 | show addendum
- 718 300 g | non-volatile memory
- 718719724725, 726 | safety guidelines
- Series 71 x | calibration manual
- Series 71 x | calibration manual addendum