雷竞技appFluke 721 precision pressure calibrator
The main features
雷竞技appFluke 721 configuration can choose 16 PSI (1.1 bar) or 36 PSI (2.48 bar) low pressure sensor, and then add any of the following seven pressure range: 100 PSI, 300 PSI, 500 PSI, 1000 PSI, 1500 PSI, 3000 PSI or 5000 PSI (6.9 bar, bar, bar, 69 bar, 103.4 24.5 bar, 200 bar, 345 bar).
- Very suitable for gas pressure instrument or equipment calibration
- Two independent stainless steel pressure sensors, the accuracy of 0.025%
- Used to measure the temperature of Pt100 RTD input, (optional) probe
- Measuring 4 to 20 mA signal
- Loop within 24 V power supply for the transmitter power supply under test
- Can measure up to 30 V direct current, check the 24 V power supply circuit
- Connect 700 series external pressure module extension range (29 range)
- Most large size backlight figure display screen can display three input at the same time
- Store five instrument Settings for your calls and use
Produc雷竞技appts overview: Fluke 721 precision pressure calibrator
Applicable to pressure calibration and temperature measurement
雷竞技appFluke 721 precision pressure calibrator is an ideal tool for a gas airtight transportation applications.With the aid of the calibrator is equipped with two independent pressure sensors, just use this kind of calibration tool can measure the static pressure and differential pressure at the same time.
View: total pressure calibration solution, all the problem solved
Produc雷竞技appt specifications: Fluke 721 precision pressure calibrator
Technical specification (1 year) | |||
雷竞技appFluke - 721-1601 | range | The resolution of the | precision |
Low pressure sensor | |||
- 14 psi to + 16 psi 0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
- 12 psi to + 100 psi 0.83 bar to 6.9 bar |
0.01 psi, 0.0001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-1603 | Low pressure sensor | ||
- 14 psi to + 16 psi 0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
- 12 psi to + 300 psi - 0.83 bar - 20 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-1605 | Low pressure sensor | ||
- 14 psi to + 16 psi 0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
- 12 psi to + 500 psi 0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-1610 | Low pressure sensor | ||
0 psi to + 1000 psi 0.00 bar - 69 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
High pressure sensor | |||
- 12 psi to + 500 psi 0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-1615 | range | The resolution of the | precision |
Low pressure sensor | |||
- 14 psi to + 16 psi 0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to + 1500 psi 0.00 bar to 103.4 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-1630 | Low pressure sensor | ||
- 14 psi to + 16 psi 0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to + 3000 psi 0.00 bar - 200 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
雷竞技appFluke - 721-1650 | Low pressure sensor | ||
- 14 psi to + 16 psi 0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to + 5000 psi 0.00 bar - 345 bar |
0.1 psi, 0.01 bar |
0.035% of full scale | |
雷竞技appFluke - 721-3601 | range | The resolution of the | precision |
Low pressure sensor | |||
- 14 psi to + 36 psi 0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
- 12 to + 100 psi, 0.83 bar to 6.9 bar |
0.01 psi, 0.0001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-3603 | Low pressure sensor | ||
- 14 psi to + 36 psi 0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
- 12 psi to + 300 psi - 0.83 bar - 20 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-3605 | Low pressure sensor | ||
- 14 psi to + 36 psi 0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
- 12 psi to + 500 psi 0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-3610 | range | The resolution of the | precision |
Low pressure sensor | |||
- 14 psi to + 36 psi 0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to + 1000 psi 0.00 bar - 69 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
雷竞技appFluke - 721-3615 | Low pressure sensor | ||
- 14 psi to + 36 psi 0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to + 1500 psi 0.00 bar to 103.4 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
雷竞技appFluke - 721-3630 | Low pressure sensor | ||
- 14 psi to + 36 psi 0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to + 3000 psi 0.00 bar - 200 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
雷竞技appFluke - 721-3650 | Low pressure sensor | ||
- 14 psi to + 36 psi 0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to + 5000 psi 0.00 bar - 345 bar |
0.1 psi, 0.01 bar |
0.035% of full scale | |
General technical specifications | |||
Instrument set up call | The use of electricity when previous Settings | ||
Using the environment | Working temperature - 10 ° C to + 50 ° C Storage temperature (without battery) - 20 ° C to + 60 ° C |
||
At an altitude of | 2000 m | ||
Protection grade | IP - 40 | ||
The power supply requirements | 6.0 V dc | ||
Battery life | > 35 hours (for main purpose) | ||
The battery number | (4) the standard number 5 batteries | ||
Size (high x width x deep) | 7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm) | ||
The weight of the | 03539 kg (1 lb 3 oz) | ||
The connector/port pressure | Two, 1/8 in the NPT, 700 p series pressure module: RTD probe | ||
Electrical and temperature measurement (1 year) | |||
function | range | The resolution of the | precision |
MA measurement | 0 to 24 mA | 0.001 mA | Readings of plus or minus 0.015% + / - 0.002 mA |
V DC measurement | 0 to 30 V dc | 0.001 V | Readings of plus or minus 0.015% + / - 0.002 V |
Temperature measurement (RTD/Ohms) creates | To 40 ° C to 150 ° C (to 40 ° F to 302 ° F) |
0.01 ° C, 0.01 ° F | Readings of plus or minus 0.015% + / - 0.02 ohms + / - 0.1 ° C (+ / - 0.2 ° F) Using 720 RTD probe attachment is + / - 0.25 ° C (+ / - 0.45 ° F) synthesis of uncertainty |
Circuit power | 24 V | N/A | 24 mA @ 24 V |
1. The RTD t雷竞技appemperature measurement need to use Fluke - 720 Pt - 100 RTD probe option as attachments | |||
The temperature influence | |||
15 ° C - 35 ° C for all functions within the scope of the accuracy of no effect | |||
Temperature beyond 15 ° C - 35 ° C, add + / - 0.002% f.s / ° C | |||
Pressure unit | |||
Psi, bar, mbar, kPa, kgcm2, cmH2O @ 4 ° C, cmH2O @ 20 ° C, mH2O @ 4 ° C, mH2O @ 20 ° C, inH2O @ 4 ° C, inH2O @ 20 ° C, inH2O @ 60 ° F, mmHg @ 0 ° C, inHg @ 0 ° C and ftH2O @ 4 ° C, ftH2O @ 20 ° C, ftH2O @ 60 ° F |
Mode雷竞技appl: Fluke 721 precision pressure calibrator
16 psi, 100 psi pressure calibrator double sensor
- Double transducer pressure calibrator, 16 PSIG, 100 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
16 psi double sensor and 300 psi pressure calibrator
- Double transducer pressure calibrator, 16 PSIG, 300 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
16 psi double sensor and 500 psi pressure calibrator
- Double transducer pressure calibrator, 16 PSIG, 500 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
16 psig, 1000 psig, double sensor pressure calibrator
- Double transducer pressure calibrator, 16 PSIG, 1000 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
16 psig, 1500 psig, double sensor pressure calibrator
- Double transducer pressure calibrator, 16 PSIG, 1500 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
16 psi, 3000 psi, the double sensor pressure calibrator
- Double transducer pressure calibrator, 16 PSIG, 3000 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
16 psi, 5000 psi, the double sensor pressure calibrator
- Double transducer pressure calibrator, 16 PSIG, 5000 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
Psi, 36, 100 psi, the double sensor pressure calibrator
- Double sensor pressure calibrator, 36 PSIG, 100 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
Psi, 36, 300 psi, the double sensor pressure calibrator
- Double sensor pressure calibrator, 36 PSIG, 300 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
Psi, 36, 500 psi, the double sensor pressure calibrator
- Double sensor pressure calibrator, 36 PSIG, 500 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
Psi, 36, 1000 psi, the double sensor pressure calibrator
- Double sensor pressure calibrator, 36 PSIG, 1000 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
Psi, 36, 1500 psi, the double sensor pressure calibrator
- Double sensor pressure calibrator, 36 PSIG, 1500 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
Psi, 36, 3000 psi, the double sensor pressure calibrator
- Double sensor pressure calibrator, 36 PSIG, 3000 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead
Psi, 36, 5000 psi, the double sensor pressure calibrator
- Double sensor pressure calibrator, 36 PSIG, 5000 PSIG
- Soft package
- Four (4) aa batteries
- manual
- Traceable calibration certificates
- The test lead