雷竞技appFluke 772 milliamperes process clamp type table
The main features
雷竞技appThe function of the Fluke 772 mA clamp table:
- Good accuracy of 0.2%
- 0.01 mA sensitivity and resolution
- Without "disconnect circuit can measure 4 to 20 mA signal
- Measurement of PLC and analog I/O mA signal control system
- It can display mA measured value and the percentage of 4 to 20 mA range double backlit display
- Measuring spot light up the darkness is difficult to found inside the case
- With extension cords detachable clamp table, can be measured in the narrow space
- Use 99.9 mA range measurement control system of the old is 10 to 50 mA signal
- Automatically change 4 to 20 mA output for remote testing
- Automatically shut down, the power saving function such as backlight timeout can prolong battery life
- "Keep function can capture and display the measured value of the constantly changing
- Through the pens and "access circuit function measurement 4 to 20 mA signal
- Synchronous circuit power supply 24 v and measurement circuit of mA signal, can transport device for power supply and test it
- 4 to 20 mA output signal source to test the control system I/O or I/P
- MA output linear gradient or 25% output step by step
- Automatically change 4 to 20 mA output for remote testing
selections5482.00
Produc雷竞技appts overview: Fluke 772 milliamperes process clamp type table
Need more time?
When performing 4-20 mA signal measurement don't disconnect the circuit, and save time.
You are wasting valuable time?
- By removing the line and disconnect the circuit to perform the mA measurement
- Call control room to isolate circuits
- Test the analog input/output on the console
- Rule out with mA fault of input and output device
- Repair the intermittent problems or unstable 4-20 mA loop
- Return to shop for other tools
If you are always busy雷竞技app, never enough time, then try the Fluke 772 milliampere clamp type table.These pliers type table do not need to perform some time wasting activities, can greatly save time and money.Now, you don't have to disconnect the circuit or closed system, 4-20 mA loop can diagnose and repair.
Belo雷竞技appw is a Fluke 772 clip-on table can provide some help for you:
Ma clamp table properties | application | How to save time and money |
Without disconnect circuit measurement of PLC and analog I/O mA signal control system | Measuring the weak direct current (dc) | Make the process instructions associated with real physical values |
Don't need to disconnect the circuit can output signal transmission device | Without disconnect circuit maintenance and diagnosis process and automation equipment | Don't interrupt the process |
With extension of detachable grips table | Measurement can be performed in a narrow space | Allow measurement in all sorts of difficult circumstances |
Measuring the spotlight | Light in the darkness of the chassis is difficult to find | Measurement process easier and faster |
In non-contact way maximum measuring current of 99.9 mA | The broad range | In the old control system of measuring 10 to 50 mA signal |
Automatically shut off the power | Automatically shut down after 15 minutes and 2 minutes backlighting and spotlight | Extend the life of the battery |
Produc雷竞技appt specifications: Fluke 772 milliamperes process clamp type table
Technical indicators | ||
To measure the diameter of the conductor | 0.177 "or 4.5 mm (maximum) | |
Working temperature | - 10-50 DHS C | |
Storage temperature | - 25 - DHS 60 C | |
Working humidity | < 30 DHS when C < 90%, 30 to 55 DHS when C < 75% | |
Work at an altitude of | 0-2000 m | |
IP protection grade | IP 40 | |
size | 44 x 70 x 246 mm (2 x 5 delighted many customers and 7/8 5/8 x 11 in) | |
The weight of the | 410 g (14.4 oz) | |
vibration | 2 grams, the randomness of 5 to 500 hz | |
The impact | Except 1 m drop test (nip) | |
EMI/RFI | In accordance with EN61326-1 | |
Related with the current measurement of jaw clip, for 1 to 3 v/v/m m the EMC of magnetic field strength 1 ma to specifications. | ||
The temperature coefficient of | 0.01% DHS C (18 DHS C < or > 28 DHS C) | |
Power supply and battery life | (4) AA 1.5 V alkaline batteries, IEC LR6, 12 hours, mA output driver 500 ohms | |
Warranty period | Three years of electronic products | |
Cable and clamp table accessories warranty for one year | ||
Functional specifications | ||
Measurement (mA) is measured by the clamp table | Resolution/range | 0 and 20.99 mA |
precision | 0.2% + 2 words | |
Resolution/range | 21.0 mA to 100.0 mA | |
precision | 1% + 5 words | |
MA measurement (measured with the test socket series) | Resolution/range | 0 and 24.00 mA |
precision | 0.2% + 2 words | |
MA output (24 mA mA driver: drive 1000 ohms) | Resolution/range | 0 and 24.00 mA |
precision | 0.2% + 2 words | |
MA simulation (maximum voltage 50 V dc) | Resolution/range | 0 and 24.00 mA |
precision | 0.2% + 2 words |
Proc雷竞技appess models: Fluke 772 milliamperes pliers type table
雷竞技appFluke 772
Ma process clamp type table
Attachment:
- 4 AA alkaline batteries (installed)
- Soft portable package
- TL75 test line
- AC 72 detachable clamp
- TL 940 miniature hook test line
- The instructions
- With Velcro Velcro belt hanging tool