雷竞技appFluke i3000s Flex type AC current clamp table, 4 suites
The main features
- Three ranges
- 30 A
- 300 A
- 3000 A, 1, 10 or 100 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm (7) in
- The CAT III 600 V safety rating
Produc雷竞技appts overview: Fluke i3000s Flex type AC current clamp table, 4 suite
I3000s Flex is a adopts the principle of AC Rogowski current clamp table.When used with oscilloscope, recording instrument or data recorder, it can measure up to 3000 a current.Flexible light measuring head allows the user to quickly and easily measured in inaccessible places.
- Three range: 30 A and 300 A and 3000 A.1, 10 or 100 mV/A output
- Very suitable for measuring is not easy to close on the coarse wire of electric current, without having to cut off the circuit
- The largest wire diameter of 178 mm
- The CAT III 600 V safety certification
Produc雷竞技appt specifications: Fluke i3000s Flex type AC current clamp table, 4 suite
Electrical specifications | |
Current range | 30 A |
300 A | |
3000 A | |
AC RMS | |
The output sensitivity (exchange coupling) | 100 mV |
10 m. | |
1 mV/A | |
The load impedance | Minimum 100 k Ω |
precision | + 25 ° C temperature |
The range of + / - 1% (45 Hz - 65 Hz) | |
linearity | From 10% to 100% range |
Readings of plus or minus 0.2% | |
noise | 8 mV AC RMS (30 A) |
2 mV AC RMS (300 A, 3000 A) | |
Frequency range | 10 Hz to 50 kHz (3 dB) |
Phase error | "Plus or minus 1 ° (45 Hz - 65 Hz) |
Plus or minus 10 ° (20 kHz) | |
Position the sensitivity | From the connection point at the beginning of the cable length > 25 mm |
Range of plus or minus 2% | |
Field effect | Starting from the measuring head when cable length > 200 mm |
Range of plus or minus 1% | |
The power supply | 2 AA/MN 1500 / LR6 alkaline batteries, 400 hours, low battery indicator |
The temperature coefficient of | Readings of plus or minus 0.08% / ° C |
Working voltage | See section "safety standard" |
600 V AC RMS or DC | |
General technical specifications | |
Measuring head circumference | 610 mm (24) in |
Measuring head cable diameter | 14.3 mm (0.56 in) |
Measuring head bending radius | 38.1 mm (1.5 in) |
Cable length (measuring head to electronic components) | 2 m (6.56 ft) |
Output connection | With 0.5 m cable, terminal security BNC connectors.With 4 mm safety plug adapter |
Working temperature range | - 20 ° C to + 90 ° C (4 ° F to 190 ° F) (measurement) |
- 20 ° C to + 85 ° C (4 ° F to 185 ° F) (electronic components) | |
Wide temperature range | To 40 ° C to + 105 ° C (to 40 ° F to 221 ° F) (measurement) |
- 20 ° C to + 85 ° C (4 ° F to 185 ° F) (electronic components) | |
Working humidity | From 15% to 85% (condensate) |
The weight of the | 180 g (0.396 lb) (measurement) |
190 g (0.419 lb) (electronic components) | |
Safety standards | BS EN 61010-1:2001 |
BS EN 61010-2-032:2002 | |
BS EN 61010-031:2002 | |
600 Vrms, class III, pollution level 2 | |
Using probe on uninsulated conductor is limited to 600 V ac RMS or dc, and the frequency of 1 KHZ | |
EMC standard | EN 61326:1998 + A1, A2 and A3 |
The largest wire size can be obtained | 610 mm or 914 mm, depending on the model |
Mode雷竞技appl: Fluke i3000s Flex type AC current clamp table, 4 suite
雷竞技appFluke i3000 Flex 4 pk
雷竞技appFluke i3000s Flex type AC current clamp table, 4 suites