China

I6000sFlex AC current meter

  • 雷竞技appFluke i6000sFlex AC Current Probe

Products overview: i6000sFlex AC current meter

I6000sflex is a manufactured Rogowski principle of AC current meter.When used with oscilloscope, recording instrument or data recorder, it can measure up to 6000 a current.Flexible light measuring head allows the user to quickly and easily measured in inaccessible places.

Product specifications: i6000sFlex AC current meter

Electrical characteristics
Current range 60 A / 600 A / 6000 A ac RMS
The output sensitivity (exchange coupling) Each amp 50 mV / 5 mV / 0.5 mV
The load impedance At least 100 kOhm
Precision (+ 25 ° C) Range of plus or minus 1% (45 to 65 hz)
Linearity (range 10% to 100%) Readings of plus or minus 0.2%
noise 8 mV AC RMS (60 A)
600/6000 2 mV AC RMS (A)
Frequency range 10 Hz to 50 kHz (3 dB)
Phase error "Plus or minus 1 ° (45 to 65 Hz)
Plus or minus 10 ° (20 kHz)
Position sensitivity (cable joint 25 mm) above Range of plus or minus 2%
Outfield effect (cable distance measuring head more than 200 mm) Range of plus or minus 1%
The power supply 2 AA MN 1500 LR6 alkaline batteries
400 hours low power special instructions or external power supply
The temperature coefficient of Readings of plus or minus 0.08% / ° C
Working voltage (see section "safety standard") 600 V AC RMS or DC
Regular feature
Measuring head cable length (double insulation) 610 mm (24) in I6000s Flex - 24
915 mm (36) in I6000s Flex - 36
Measuring head cable diameter The 14.3 mm
Measuring head bending radius The 38.1 mm
Cable length (measuring head to electronic components) 2 m.
Output connection With 0.5 m cable, terminal security BNC connectors
With 4 mm safety plug adapter
Working temperature range - 20 to + 90 ° C (measurement)
- 20 to + 85 ° C (electronic components)
Storage temperature range - 40 to + 105 ° C (measurement)
- 20 to + 85 ° C (electronic components)
Working humidity From 15% to 85% (condensate)
The weight of the 180 g (measuring head), 190 g (electronics)
Safety standards
BS EN 61010 1:2001
BS EN 61010 2-032:2002
BS EN 61010 A 031-2002
600 V RMS, CAT III, pollution level 2
EMC standard BS EN 61326:1998 + A1, A2 and A3
Using probe on uninsulated conductor is limited to 600 V ac RMS or dc, and the frequency of 1 KHZ

Model: i6000sFlex AC current meter

雷竞技appFluke - i6000s Flex - 24

雷竞技appFluke I6000S Flex - 24 AC Current Probe

The i6000sflex is an AC current probe utilizing The Rogowski principle. It can be 2 measure currents from 6 A to 6000 A when 2 in conjunction with oscilloscopes, recorders or data loggers.