雷竞技appFluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
The main function
雷竞技appFluke 116 digital multimeter (Electricians design, engineering by a Fluke.
- 雷竞技appFluke 116 HVAC with temperature and microampere meter.
- TL175 hard point test lead group.
- TPAK magnetometer rope kit.
- With Flexible Cuff Pipe hook type thermocouple.
- Sonde 80 bk integrated temperature.
- 80 ak - A thermocouple adapter.
- C115 luxury soft carrying case with shoulder straps.
雷竞技appFluke 323 true RMS hook table (durable, reliable and accurate)
- 400 A ac current measurements.
- 600 V ac and dc voltage measurement.
- The precise measurement of the nonlinear true RMS ac voltage and current signals.
- The continuity of resistance measurement is as high as 40 k Ω detection.
- Ultra-thin, accord with human body engineering design
- Meet safety level: the CAT III 600 V, 300 V/CAT IV.
Produc雷竞技appts overview: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
This product has been discontinued
For the complete solution of HVAC troubleshooting additional value packaging HVAC multimeter and hook table suite, provides the solution, and by providing all the accessories, the more effective problem solving HVAC professional contract execution cases will be required.
Spec雷竞技appification: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
雷竞技appFluke 116 HVACMultimeter andTemperature,Micro ampere
Technical specifications | |
anyTerminal and earthingbetweentheThe biggestvoltage | 600 V |
Surge absorption protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2. |
display | 6000 yuan, 4 update/per second. |
A histogram | 33, 32 update/per second. |
Working temperature | - 10 ° C to + 50 ° C |
Storage temperature | To 40 ° C to + 60 ° C |
The battery type | 9 volt Alkaline, NEDA 1604 a/IEC 6 lr61 |
Battery life | A typical 400 hoursAnd nobacklight. |
Precision specifications | ||
DCMv, | range | 600 mV |
resolution | 0.1 mV | |
The accuracy of | Plus or minus ([% of reading] + [bit]) : 0.5% + 2 | |
The DC voltage | Range/resolution | 6.000 V / 0.001 V |
Range/resolution | 60.00 V / 0.01 V | |
Range/resolution | 600.00 V / 0.1 V | |
The accuracy of | Plus or minus ([% of reading] + [bit]) : 0.5% + 2 | |
Automatic voltage | range | 600 V |
resolution | 0.1 V | |
The accuracy of | 2.0% + 3 (DC, 45 Hz - 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
AC millivolts1True RMS - | Liang Cheng | 600.0 mV |
resolution | 0.1 mV | |
The accuracy of | 1.0% + 3 (DC, 45 Hz - 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
AC volts1True RMS - | Range/resolution | 6.000 V / 0.001 V |
Range/resolution | 60.00 V / 0.01 V | |
Range/resolution | 600.0 V / 0.1 V | |
The accuracy of | 1.0% + 3 (DC, 45 Hz - 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
continuity | range | 600 Ω |
resolution | 1 Ω | |
The accuracy of | Beeper on < 20 Ω off > 250 Ω;Detects opens the or shorts of 500 mu s or longer. | |
ohm | Range/resolution | 600.0 Ω / 0.1 Ω |
Range/resolution | 6.000 k Ω Ω / 0.001 k | |
Range/resolution | 60.00 k Ω Ω / 0.01 k | |
Range/resolution | 600.0 k Ω Ω / 0.1 k | |
Range/resolution | Ω 6.000 M / 0.001 M Ω | |
The accuracy of | 0.9% + 1 | |
Range/resolution | Ω 40.00 M / 0.01 M Ω | |
The accuracy of | 1.5% + 2 | |
Diode test | Range/resolution | 2.000 V / 0.001 V |
The accuracy of | 0.9% + 2 | |
capacitance | Range/resolution | 1000 nF / 1 nF |
Range/resolution | 10.00 u F / 0.01 u F | |
Range/resolution | 100.0 u F / 0.1 u F | |
Range/resolution | 9999 mu F u F / 1 | |
Range/resolution | 100 mu to 1000 mu F F | |
The accuracy of | 1.9% + 2 | |
Range/resolution | > 1000 mu F | |
The accuracy of | 5% + 20% | |
LoZcapacitance | range | 1 nF - 500 u F |
The accuracy of | 10% + 2 typical values | |
The temperature2(K type thermocouple) | Range/resolution | To 40 ° C to 400 ° C / 0.1 ° C |
The accuracy of | 1% + 102 | |
Range/resolution | To 40 ° F to 752 ° F / 0.2 ° F | |
The accuracy of | 1% + 182 | |
AC mu amps true RMS (45 Hz - 500 Hz) - | Range/resolution | 600.0 mu A / 0.1 mu A |
The accuracy of | 1.0% + 2 | |
DC mu amps | Range/resolution | 600.0 mu A / 0.1 mu A |
The accuracy of | 1.0% + 2 | |
Hz (voltage or current output)2 | Range/resolution | 99.99 Hz / 0.01 Hz |
Range/resolution | 999.99 Hz / 0.1 Hz | |
Range/resolution | 9.999 Hz / 0.001 Hz | |
Range/resolution | 50.00 Hz / 0.01 Hz | |
The accuracy of | 0.1% + 2 |
Note:
1)allACVoltage rangeFrom 1% to100The % ofrangeWithin theThe specifiedIn addition toAuto - V/LoZthe.Auto - V/LoZThe specifiedFrom 0.0V.
2)The temperatureError (accuracy)Does not containThermocouple sondeerror.
3)The frequency iscommunicationcoupling,Ac voltagefor5Hz to 50 kHz,frequencyDC coupling,45 Hz to5kHzAlternating current.
4) temperature range/resolution: - 40 ° F to 752 ° F / 0.2 ° F
The mechanical and general specifications | |
size | 167 x 84 x 46 mm (6.57 "x 3.31" x 1.82 ") |
The weight of the | 550 g |
Warranty period | 3 years |
雷竞技appFluke 323 true RMS hook table
Technical specifications | ||
AC current | 400.0 A range | |
The accuracy of | 2% plus or minus 5 who leads (45 Hz to 65 Hz) 2.5% plus or minus 5 who leads (65 Hz - 400 Hz) |
|
The AC voltage | range | 600.0 V |
The accuracy of | 1.5% plus or minus 5 who leads | |
The DC voltage | range | 600.0 V |
The accuracy of | 1.0% plus or minus 5 who leads | |
resistance | range | 400.0 Ω Ω / 4000 |
The accuracy of | 1.0% plus or minus 5 who leads | |
continuity | 70 or less Ω | |
AC response | True RMS - | |
Keeping data | is | |
size | H x W x D (mm) | 207 x 75 x 34 |
The biggestDiameter of wire | 30 mm (MCM) 600 | |
The weight of the | 265 g | |
categorylevel | The CAT III 600 V The CAT IV 300 V |
|
Warranty period | Two years |
Mode雷竞技appl: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
Includes Multimeter and Clamp Meter
雷竞技appFluke 116 HVAC Multimeter includes:
- TL175 Hard Point Test Lead the Set
- TPak ToolPak Magnetic Meter Hanging Strap
- Flexible Cuff Pipe Clamp Thermocouple
- 80 bk Integrated Temperature Probe
- 80 ak - A Thermocouple Adapter
- C115 Deluxe Soft their Case with Shoulder Strap
雷竞技appFluke 323 True RMS Clamp Meter includes:
- The User 's manual
Manual + 雷竞技appresources: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
- 116 | use manual
- 323/324/325 | use manual
- 110/113/114/115/116/117 | safety data sheet
- 114, 115, 116, and 117 | calibration manual
- 117, 116115114113 and 110 Plus | volatile memory
- 302 + / 303/305/323/324/325 | volatile memory
- 323/324/325 | calibration manual
- 323/324/325 | appendix calibration manual
- 323/324/325 | quick reference guide
- 雷竞技appFluke 116 True RMS Multimeter | quick reference guide